The current program can be changed at this stage by rotating MFB. When MFB is pushed the current 
program can be modified. When the MFB button is pressed and hold 

for 2 seconds the menu “Settings 

and Information” will be launched.

 

The elevator can be controlled by the button “STOP”:

 

-

 

Press and hold the “STOP” button for the elevator to start in the opposite direction of the 

previous one; 

-

 

Press short the button “STOP”

 to stop the elevator movement. 

Press the “START” button to start the furnace under the current program.

 

3.2. Program modification 

In this mode by rotating MFB changes the parameter (blinking cursor is occurring). 

Temperature value changes with 10 degrees, 

time values 1 hour (except ‘’Opening time’’ which changes 

with 1 min value), second pressing of MFB changes the temperature value with 1 degree (except 

‘’Opening time’’ –

 1 sec). The input value will be confirmed with another pressing of the MFB or 

cancel

led by pressing the button “STOP.

 

 

When changing the program name, first rotate the MFB to change the cursor position. When MFB is 
pressed enters the symbol changing regime (the display shows a table with input symbols). By rotating 
the MFB changes the de

sired value and pressing the MFB confirms it. By the “STOP” button the symbol 

changing is cancelled. ‘’START’’ button deletes the symbols.

 

Exit from this mode is executed by the button ‘’STOP’’. 

 

 

3.3. Menu 

Settings and Information

 

This menu has the following options: 

-

 

Temperature values 

 setting of the furnace temperature values (C/F). 

-

 

Display brightness 

 by rotating the MFB display brightness intensity changes. 

-

 

Display off 

 number of minutes before the display switches off (screensaver activation). When 

the 0 value is set this function is deactivated. 

-

 

Sound 

 on/off sound signalization. 

-

 

Date and hour 

 clock setting. 

-

 

Cycles count 

 cycles number counter. 

-

 

Serial number. 

-

 

Software version. 

-

 

Language 

 Change the language 

 English/Bulgarian 

 

3.4. Program execution. 