The characteristics of each element are the following:  

E l e m e n t  

T e m p e r a t u r e   S e n s o r   E l e m e n t  

H u m i d i t y   S e n s o r   E l e m e n t  

S p e c i f i c a t i o n s  

R e s i s t a n c e   T e m p e r a t u r e   D e t e c t o r  

P t 1 0 0  

H i g h   P o l y m e r   E l e c t r i c   C a p a c i t y  

T y p e  

Measuring 

Range 

-40 to +100

 

0-100%RH 

-25 to 100

 

Measuring 

Accuracy 

±

0.15

0.002

t ]

 

Sensor 

JIS-C1604-1997

 

Class A equivalent  

 

Temperature 

Coefficient  

 

±0.03%RH/

 

(15 to 55

 

200kHz) 

Response Speed  

(90% response)  

16 sec.: At the wind speed of 1m/sec.  

15 sec.: If membrane filter is used  

60 sec.: If BH  

Output Signal 

Pt100

Ω    Resistance Value

 

Electric Capacity  

Consumption 

Current 

1mA or lower  

 

 
4.    Chemical Resistance  

 

        If the product is used  in an atmosphere with  an organic solvent and other active gases, such as ozone, 

ethylene oxide, acid, and al kaline, accurate relative humidity may not be achieved depending on the 
level of concentration of the said chemical substance s. 
Please consult with us if the product is to be used  in such an environment.  

 
5.    Things to  Be Noted in Handling the Product  
   

 

Upon using this product, please take note of the following:  

     

(1) Do not apply  a strong force on the product. 

     

(2) Do not leave the product under condition s that cause high heat, such as direct sunlight,   

for a long time.  

     

(3) Do not soak the product in water.  

     

(4) Do not touch the sensor element directly with  your hand. Use tweezers to attach/remove the 

sensor element. Be careful not to damage the sensor element.  

     

(5) Supplying voltage with  a value beyond the permissible range may cause the product to generate  

an erroneous output.  

       

  Make sure to keep the supply voltage within the specified range. Excessive supply voltage may 

cause damage to the electric circuit.  

     

(6) Do not bend  the cable between the sensor and casing and  the output cable to a sharp angle.  

     

(7) Do not wipe the product with benz ene and thinner.  

     

(8) Do not adjust or improvise the internal circuit. Doing so may lower the output accuracy.  

     

(9) Prevent the protective cap  from contact  with other metal parts.  

            (10) It is recommended to calibrate the output once every few months using  an accurate hygrometer.  

(11) Install the product  in a direction where TSM-H2/H3 with the current output specification will 

not be affected by the heat generated by the electric circ uit of the main unit.  

(12) Use only the designated AC -DC adapter. 

   

(If option is selected)  

   

 

6.    Sensor Replacement  

 

              In case measurement accuracy is out of the specified range at Item 5 -(10), replace the humidity 

sensor element 

TI-A

 in accordance with the following procedures:  

   

   

(1) Remove the protective cap and pull out the humidity sensor module.  

     

(2) Insert the new module into the socket section and attach the protective cap.  

     

(3) Calibrat e the unit using  an accurate hygrometer  before using it . 

Summary of Contents for TSM-H2

Page 1: ...n 2 2 Structure and Method of Connection 2 3 Specifications 2 4 Chemical Resistance 3 5 Things to Be Noted in Handling the Product 3 6 Replacement of Sensor 3 7 Warranty Period 4 8 Disclaimer 4 9 D i...

Page 2: ...are the following Usable Temperature Range Main Unit 5 to 55 Sensor Section 25 to 100 Measuring Humidity Range 0 to 100 RH Measuring Accuracy at 25 For TSM H2 2 RH 10 to 90 RH 3 RH 2 to 10 RH 90 to 10...

Page 3: ...or a long time 3 Do not soak the product in water 4 Do not touch the sensor element directly with your hand Use tweezers to attach remove the sensor element Be careful not to damage the sensor element...

Page 4: ...ent See the Warranty Period of Humidity Sensor Element TI A for the sensor section We will repair the product free of charge for any trouble due to our fault within this period However please be noted...

Page 5: ...L type 50mm 3 5 m m 50mm 460mm 40mm 38mm 55 25 1 4 2000mm 3 8 m m Hum i di ty Se n sor E l em en t T I A T em per a tur e S en s or E lem e n t P t 10 0 Se n so r Pr o tec ti ve Ca p Se n so r Pr o te...

Page 6: ...tline Drawing Duct Type Rubber Packing Main Unit M4 Countersunk Screw 40mm or pan head tapping screw Drilling location for duct etc Two positions If the tapping screw is used the hole diameter depends...

Page 7: ...t TSM H2 H3 20120301 1 DC 9 25V I mA V For Voltage Output For Current Output Blac k B G ree n b Fo r tem per a tur e s en s or elem en t Y ello w A Pur ple Bl u e DC P owe r C on tr olle r etc Blac k...

Reviews: