Communication manual TOHO ELECTRONICS INC.
DWG.No. 4B-6829-A
- 32 -
TOHO
MODBUS
Name
Command
Remark
First
Identifier
Second
Identifier
Absolute
(DEC)
Relative
(hex)
AS1
01
41377
0560
CH1 Alarm1 Alarm Value
RW
Temperature input
:
0.0
℃
unit
Analog input
:
1 digit unit
AS1
02
41379
0562
CH2 Alarm1 Alarm Value
RW
AS1
03
41381
0564
CH3 Alarm1 Alarm Value
RW
AS1
04
41383
0566
CH4 Alarm1 Alarm Value
RW
AS1
05
41385
0568
CH5 Alarm1 Alarm Value
RW
AS1
06
41387
056A
CH6 Alarm1 Alarm Value
RW
AS2
01
41389
056C
CH1 Alarm2 Alarm Value
RW
AS2
02
41391
056E
CH2 Alarm2 Alarm Value
RW
AS2
03
41393
0570
CH3 Alarm2 Alarm Value
RW
AS2
04
41395
0572
CH4 Alarm2 Alarm Value
RW
AS2
05
41397
0574
CH5 Alarm2 Alarm Value
RW
AS2
06
41399
0576
CH6 Alarm2 Alarm Value
RW
AS3
01
41401
0578
CH1 Alarm3 Alarm Value
RW
AS3
02
41403
057A
CH2 Alarm3 Alarm Value
RW
AS3
03
41405
057C
CH3 Alarm3 Alarm Value
RW
AS3
04
41407
057E
CH4 Alarm3 Alarm Value
RW
AS3
05
41409
0580
CH5 Alarm3 Alarm Value
RW
AS3
06
41411
0582
CH6 Alarm3 Alarm Value
RW
AS4
01
41413
0584
CH1 Alarm4 Alarm Value
RW
AS4
02
41415
0586
CH2 Alarm4 Alarm Value
RW
AS4
03
41417
0588
CH3 Alarm4 Alarm Value
RW
AS4
04
41419
058A
CH4 Alarm4 Alarm Value
RW
AS4
05
41421
058C
CH5 Alarm4 Alarm Value
RW
AS4
06
41423
058E
CH6 Alarm4 Alarm Value
RW