9
DIGITAL TORQUE WRENCH “DATA TORK” MODEL
CEM3-G
5
Explanation of each mode
CEM3 basic functions are categorized in the following "MODE".
(1)
Memory mode
M-3 mode: M-3 is set as delivery setting. M-3 mode can save max.999 pc of data and the
measured time. However, M-3 mode is not compatible with Tohnichi data filing software
(DFS).
M-2 mode: M-2 is compatible with the old CEM2 model. M-2 mode can save only 99pc of
data (same as CEM2). However, M-2 mode is compatible with the same Tohnichi data filing
software (DFS) which was used by CEM2.
(2)
Display mode
Dual mode: Dual mode is set as delivery setting. It uses 2 displays (LCD and LED) to
display torque value, counter, measured time, etc.
LCD mode (Power saving mode): Only LCD display is used and LED is turned off to save
electricity.
(3)
Measurement mode
MODE-M (Inspection mode): MODE-M is set as delivery condition. This mode is used for
retightening and loosening inspection.
MODE-T (Tightening mode): This mode is used for tightening operation. When it reaches
the lower limit torque value, green LED lamp turns on and the alarm goes off.
(4)
Data sampling mode
Run mode: When the counter is 000(M-3 mode) or 00 (M-2 mode), it is in Run mode. In
Run mode, the display shows the torque value being applied at the moment
and returns to zero when torque is released.
Peak mode: When the counter is 001-999 (M-3 mode) or 01-99(M-2 mode), it is in Peak
mode. In Peak mode, the maximum torque will be captured and the display
hold this maximum torque value.
For detailed setting, refer to 10. Settings.
CEM3-G取扱説明書.indd 10
CEM3-G取扱説明書.indd 10
2016/07/14 11:24:55
2016/07/14 11:24:55