DIGITAL TORQUE GAUGE  MODEL 

ATGE-G

USB Interface

USB1.1 compliant (USB-serial conversion chip used)

Connector

USB mini B-type

Baud rate

2400/4800/9600/19200 bps (selectable)

Data length

8 bits

Serial Interface

Stop bit

1 bit

Parity

None

Flow control

Not control

7

External Output Specifications

• USB Output Method

The USB connection cable and communication driver are optionally available (Part No. 384).

· Preparation (PC)

(1) Install the communication driver to a USB-compliant PC.

(The communication driver is contained in the CD-ROM supplied with the product.)

(2) Make settings of the PC port and communication format.

(For installation procedure and communication settings, see the instruction manual in the

CD-ROM.)

· Preparation (ATGE-G)

(3) Turn on the power of ATGE-G.

(4) Select the communication baud rate (2400/4800/9600/19200 bps).

· Communication

(5) Connect the USB connection cable (option) to the PC and ATGE-G.

(6) Start up the communication software (The communication software is not included with

the product).

· Data output

(7) Data Output Method (See the “All measurement data output at a time”).

* Use the optionally available USB connection cable to connect to a PC.

* Connect the cables to PC before starting up the software. Otherwise, communication

may not be established.

* If the ATGE-G and multiple TOHNICHI USB serial output devices (CEM3, R-DT999,

ST2) are connected to a PC at the same time, communication may not be established.

* Do not connect ATGE-G to PC with USB cable when no battery is installed, or when the

battery is running out (Battery alarm).

• Output Format

plus (+): nothing is displayed (blank).

minus (-): "-" is displayed.

Header

Counter (3fig)

Torque (decimal point) Delimiter

ATGE-G型 取扱説明書̲CS5.indd   19

ATGE-G型 取扱説明書̲CS5.indd   19

2016/06/06   16:37:30

2016/06/06   16:37:30

Summary of Contents for ATGE-G

Page 1: ...efully before use If you have any question about the product and its operations please contact your nearest distributor or TOHNICHI MFG CO LTD ATGE G ATGE G Model MODEL ATGE G ATGE5CN G display put to...

Page 2: ...description and conduct safe operations and proper control Signal Words The signal words are the headers which indicate the level of hazard that should be know for human safety and in handling devices...

Page 3: ...ery CR2450 for power source Do not use any other battery than that specified in this operating instruction When inserting the battery be careful to ensure correct polarity Do not use or store the inst...

Page 4: ...aw chuck Do not bend or pull the cable connecting the gauge and the display The battery inside ATGE G is for sample use only and may not be fully charged Do not connect ATGE G to PC by USB cable when...

Page 5: ...o measure 13 6 Operating Examples 15 6 1 Computing function 15 6 2 All measurement data output at a time 16 6 3 Delete measurement data 17 7 External Output Specifications 18 8 Procedures of Various S...

Page 6: ...9 measurement data can be stored Data can be automatically counted by the auto memory function 9 The number of samples maximum value minimum value and average value can be displayed 10 A coin shaped l...

Page 7: ...omatically Counter Battery indicator Torque unit Measuring direction CW CCW Torque Auto memory ON When Auto memory Reset timer is set at 0 1 5 seconds Display 1 2 5 3 6 7 4 8 9 11 12 10 3 Count Forwar...

Page 8: ...ed to reset the peak value or to delete the stored data In the RUN mode auto zero adjustment is performed 8 External Output Terminal This is the terminal for connecting the USB connection cable option...

Page 9: ...o Zero function In RUN mode press the clear key to activate the auto zero function However the torque load must be within about 20 of the maximum value When Err 9 is displayed Under no load condition...

Page 10: ...disappears the torque gauge functions properly If the Err message remains displayed turn off the power once then press the power switch and the clear key at the same time If it still remains the membr...

Page 11: ...ttery status in 4 steps There is enough battery remaining Remaining battery amount is not enough The battery life is half of the full operating time It is almost time to replace batteries Battery alar...

Page 12: ...e that there is enough battery remaining If the battery indicator is ashing change the batteries Note The body and display part is connected by a cable be careful not to damage the cable Be careful no...

Page 13: ...e to hold the chuck holder fixed Either in RUN mode 000 or PEAK mode 001 999 rotate ATGE G to measure the torque It works bi directionally Note Make sure the object is clamped in the center and level...

Page 14: ...the chuck holder fixed tighten the chuck Turn on the power of the torque gauge If the counter is 000 the continuous display RUN mode is set If the counter is 001 999 PEAK mode is set It works bi dire...

Page 15: ...holder Display Fix the torque gauge Three jaw check Make sure to hold the chuck holder when rotating the three jaw chuck Turn the torque screwdriver Note Make sure to hold the chuck holder when rotat...

Page 16: ...ated Using this button set the counter at the upper limit value in the range of data to be calculated Press MD Ex 1 To calculate in the range of 001 200 Set the counter at 200 press the MD key and Stt...

Page 17: ...of data to be output Press MD Ex 1 To output data in the range of 001 200 Set the counter at 200 press the MD key and set Stt at 001 Ex 2 To output data in the range of 101 200 Set the counter at 200...

Page 18: ...e data range to delete Press MD Ex 1 To delete data in the range of 001 200 Set the counter at 200 press the MD key and set Stt at 001 Ex 2 To delete data in the range of 101 200 Set the counter at 20...

Page 19: ...E G 3 Turn on the power of ATGE G 4 Select the communication baud rate 2400 4800 9600 19200 bps Communication 5 Connect the USB connection cable option to the PC and ATGE G 6 Start up the communicatio...

Page 20: ...ncel The display returns to the measurement display Proceed without saving Unit conversion table Conversion factors 8 2 PEAK mode change PEAK mode change P 1 PEAK measuring mode Captures the peak and...

Page 21: ...l saving set it to 00 Press to save the setting and proceed to next The display returns to the measurement display TProceed without saving 8 4 Baud rate setting Change the baud rate setting 2400 4800...

Page 22: ...the battery forward pull it up Remove the battery and replace it with a new one Battery cover Battery 6 After changing batteries put back the battery cover Note Use the Coin shaped lithium battery CR...

Page 23: ...alibration of ATGE G the calibration device ATGTCL24CN and the calibration adapter Catalog No 808 are needed 4 Plastic chuck Part No 322 5 ATGE G Measurement plate Part No 808 It is designed for ATGE...

Page 24: ...Do not apply excessive force to the dip switch not to damage it 1 Use the USB connecting cable Part No 384 2 Slide open the battery cover on the back of the display 4 Connect USB cable A type female t...

Page 25: ...y shows as follows 7 If selected BATT Enables auto power off and residual battery indicator functions If selected USB Disables auto power off and residual battery indicator functions USB mini B type f...

Page 26: ...ue 4 digits character height 7mm Unit Battery remaining measuring direction Measurement Mode PEAK RUN Data Memory 999 readings Statistical Processing Number of samples maximum value minimum value mean...

Page 27: ...26 DIGITAL TORQUE GAUGE MODEL ATGE G Dimensions Chuck holder Reset switch Display Approx 69 Chuck diameter Chuck diameter 40 Three jaw chuck 72 6 1 to 6 5 67 67 USB terminal 3 USB cap 58 Approx 120...

Page 28: ...HI AMERICA CORP TEL 1 0 847 947 8560 FAX 1 0 847 947 8572 1303 Barclay Blvd Bu alo Grove IL 60089 U S A E mail inquire tohnichi com Website http tohnichi com TOHNICHI AMERICA CORP Atlanta O ce TEL 1 0...

Reviews: