![Tohnichi ATGE-G Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/tohnichi/atge-g/atge-g_operating-instructions-manual_1124721013.webp)
12
DIGITAL TORQUE GAUGE MODEL
ATGE-G
5-2. Rotating ATGE-G itself to measure
· Before measurement, check that ATGE-G shows 0 on the display. If it is not zero, push clear
key at no load condition and get 0.
· Hold the chuck holder fixed and open the three-jaw chuck. Place the object inside the three-
jaw chuck.
· Place the object to the center of the three-jaw chuck and close the chuck to fix the object
(When you close the three-jaw chuck, make sure to hold the chuck holder fixed).
· Either in RUN mode (000) or PEAK mode (001-999), rotate ATGE-G to measure the torque. It
works bi-directionally.
Note * Make sure the object is clamped in the center and
level is maintained for accurate measurement.
* If the object to measure is too big for the existing
three-jaw chuck to measure, a special adapter needs
to apply to measure (see below illustration).
* The object and ATGE-G must be set in stable
condition when auto zero is conducted.
Object to be measured
Chuck holder
Display
Fix the torque gauge.
Three-jaw check
Make sure to hold the chuck holder when rotating the three-jaw chuck.
24
7
M28 x P15
ø20
ATGE-G型 取扱説明書̲CS5.indd 13
ATGE-G型 取扱説明書̲CS5.indd 13
2016/06/06 16:37:27
2016/06/06 16:37:27