5. What to do in case of problems
Before contacting to the Sales Agent, please check your problems according to Table 5-1. If
problems are not applicable to Table 5-1, please enter in Table 5-2 and contact the Sales Agent.
DANGER
Turn off the power supply if you notice
abnormal conditions.
If you notice an unusual noise, vibration or any
other abnormality during operation of the
ARG
,
immediately turn off the power supply to shut
down the
ARG
.
Keeping the
ARG
running under abnormal
conditions could result in unexpected accident.
Table 5-1 Fault finding table for the
ARG
No.
Problem
Possible cause
Step to take
1
The
ARG
does not
operate
even though
the power
switch is
ON.
Power circuit is
incorrectly wired.
・
Check if primary power is available.
・
Check the connection between the power supply and
the
ARG
.
Signal circuit is
incorrectly wired.
・
Check the remote switch wiring is not open-circuited.
・
Check the safety device wiring is not open-circuited.
・
Check the connection between the Motor Driver and
the
ARG
unit.
Circuit breaker switch
is not turned on.
・
Turn on the circuit breaker switch again according to
the procedures in this manual.
Power generator is not
producing enough
power.
・
Check the capacity of the power generator, which
must exceed the mass of the total
ARG
’s power
used.
Restart of the
ARG
is
attempted before it
completely stops after
shutdown.
・
Stop the
ARG
completely, and then restart according
to the procedures in this manual.
Remote switch is not
“ON”
・
Turn on the remote switch.
Wrong starting steps
were taken (turned on
the Automatic Fast
return function).
Restart the
ARG
as follows.
①
Power generator supply: ON
②
Circuit breaker switch: ON
③
Remote switch: ON
2
Circuit
breaker
switch trips
immediately
after it has
been turned
on.
Power circuit is
incorrectly wired.
・
Check the short circuit of the power circuit between
the power generator and the
ARG
unit.
Ground fault.
・
Check the short circuit of the power circuit between
the power generator and the
ARG
unit.
3
Start check
lamp does
not light on.
Lamp bulb has blown.
・
Change the lamp bulb.
Connection failure.
・
Check the start check lamp wiring is not open-
circuited.
Power
supply ”OFF”
Summary of Contents for ANTI ROLLING GYRO ARG175T
Page 33: ...Anti Rolling Gyro MSM 17500T A1 32 Anti Rolling Gyro ARG ARG...
Page 35: ...Anti Rolling Gyro MSM 17500T A1 34 ARG ARG ARG a b c ARG ARG ARG ARG ARG ARG ARG ARG...
Page 36: ...Anti Rolling Gyro MSM 17500T A1 35 1 1 1 ARG ARG...
Page 37: ...Anti Rolling Gyro MSM 17500T A1 36 1 2 ARG...
Page 38: ...Anti Rolling Gyro MSM 17500T A1 37 1 3 ARG ARG ARG ARG ARG ARG ARG 2 ARG ARG ARG ARG ARG...
Page 41: ...Anti Rolling Gyro MSM 17500T A1 40 3 3 1 ARG ARG ARG ARG ARG ARG ARG ARG ARG ARG ARG...
Page 43: ...Anti Rolling Gyro MSM 17500T A1 42 ARG 80 90 ARG ARG ARG ARG ARG ARG ARG 3 ARG 1 3...
Page 44: ...Anti Rolling Gyro MSM 17500T A1 43 ARG ARG ARG ARG ARG ARG ARG ARG ARG 3 ARG ARG 1 ARG 3...
Page 46: ...Anti Rolling Gyro MSM 17500T A1 45 3 1 ARG 2 3 No 8 9 10 11 12 4 13 14 15 ARG 16N m...
Page 51: ...Anti Rolling Gyro MSM 17500T A1 50 4 4 ARG ARG ARG ARG ON 4 3 5 5 1 No 5 4 3 No ARG 1 ON ON...
Page 55: ...Anti Rolling Gyro MSM 17500T A1 54 6 2 6 1 ARG 2 ARG ARG ARG ARG ARG ARG ARG...
Page 56: ...Anti Rolling Gyro MSM 17500T A1 55 ARG ARG ARG 2 ARG 2 3 ARG ARG 1 ARG 3...
Page 57: ...Anti Rolling Gyro MSM 17500T A1 56 6 1 ARG 1 4 No 1 ARG ARG 2 3 ARG 130N m 4 5 ARG 6 ARG 7...
Page 59: ...Anti Rolling Gyro MSM 17500T A1 58 6 1 ARG 3 4 No 15 ARG 16 N m 16 17 18 4 19 20...
Page 60: ...Anti Rolling Gyro MSM 17500T A1 59 6 1 ARG 4 4 No 21 22 ARG 23 ARG...