Appendix C
Safety and Compliance
C1
Safety
C1.1
Mounting Warning
The Tobii Pro X3–120 should be mounted according to MANUFACTURER instructions of approved mounts.
Tobii AB or its agents are not liable for damage or injuries to a person or its property due to a Tobii Pro X3–120
falling from a mounted configuration. The mounting of a Tobii Pro X3–120 is done entirely at the user’s own risk.
The double sided tape supplied with the adhesive Magnetic Mounting Plates is designed to permanently attach the
bracket to the monitor/laptop. Attempting to remove the bracket after attaching it using the supplied tape can result in
damage both to the monitor/laptop and the bracket.
Do not lick the tape or place any part of the tape or Magnetic Mounting Plate in one's mouth.
Do not mount the Tobii Pro X3–120 on monitors positioned above the head or face of a users unless using a
dedicated "fixed mounting" solution.
C1.2
Emergency Warning
The Tobii Pro X3–120 system is to be used for research purposes only. Be aware that due to the low, but possible
risk of failure or distraction, the Tobii Pro X3–120 should not be relied upon or used in dangerous or otherwise critical
situations.
C1.3
Infrared Warning
When activated, the Tobii Pro X3–120 emits pulsed infrared (IR) light. Certain medical devices are susceptible to
disturbance by IR light and/or radiation. Do not use the Tobii Pro X3–120 when in the vicinity of such susceptible
medical devices as their accuracy or proper functionality could be inhibited.
C1.4
Epilepsy Warning
Some people with
Photosensitive Epilepsy
are susceptible to epileptic seizures or loss of consciousness when
exposed to certain flashing lights or light patterns in everyday life. This may happen even if the person has no medical
history of epilepsy or has never had any epileptic seizures.
A person with Photosensitive Epilepsy would also be likely to have problems with TV screens, some arcade games,
and flickering fluorescent bulbs. Such people may have a seizure while watching certain images or patterns on a
monitor, or even when exposed to the light sources of an eye tracker. It is estimated that about 3-5% of people with
epilepsy have this type of Photosensitive Epilepsy. Many people with Photosensitive Epilepsy experience an "aura" or
feel odd sensations before the seizure occurs. If you feel odd during use, move your eyes away from the eye tracker.
C1.5
Magnetic Field Warning
The Tobii Pro X3–120 Magnetic Mounting Plates contains magnets. Magnetic fields may interfere with the function of
cardiac pacemakers and implantable cardioverter-defibrillators. As a general rule, maintain a minimum distance of 6
inches (15 centimeters) between any item with magnets and your heart device.
The magnets can also shut off the monitor on a laptop if the laptop is equipped with a magnetic sensor to switch off
the monitor when closing the laptop. If this happens, shut of the sensor on the laptop.
10
Appendix C Safety and Compliance
Tobii Pro X3–120 Eye Tracker Product Description v.1.0.2 - en-US
Summary of Contents for X3-120
Page 1: ...Tobii Pro X3 120 Eye Tracker Product Description...
Page 4: ......