6-6
Chapter 6: APPENDIX
[Error indicator status]
Possible cause and remedy
Power off
AC adapter is disconnected.
→
Ensure the connection of power supply.
CPU error (CPU hang-up)
→
Contact your TOA dealer.
Data write error
Writing data failed because the unit's power is shut off or
other trouble occurs during data write or firmware update.
→
Contact your TOA dealer.
Firmware exception handling occurrence
→
Push the front-mounted Reset button to restart the unit
operation.
If this happens frequently, contact your TOA dealer.
Communications-related errors on network and control
Causes may be the following: Power-off or network
disconnection of the unit set to be controlled, duplicate
control (busy), NX-100/100S setting errors (impossible
control or communications settings), and network
equipment setting errors.
→
Establish a connection to the unit to be controlled, or
change settings of individual equipment.
Packet collision occurrence
The NX-100/100S and the connected network equipment
are in half-duplex communications, and collision occurs.
This may cause intermittent sound when audio signals are
transmitted.
→
It is preferable to use the NX-100/100S in full-duplex
communications.
Network disconnection
LAN cable is disconnected or network equipment is turned
off.
→
Ensure each connection to the network equipment.
Excessive audio signal input (Distorted output signal)
Audio signal level applied is excessively high.
→
Set the input volume control and the input level selection
switch appropriately.
(Flashes alternately.)
(Lights for
1 second
in several-
second
cycles)
or
1
2
3
4
5
6
7
LNK/ACT FD/COL
SIGNAL
PEAK
(NX-100S only)
STATUS
ERROR
RUN
No audio signal input
If this happens though the Audio input terminal is
connected to equipment, the cause may be the following
case: the external equipment is turned off, or its
connection cable is disconnected, or the NX-100S input
volume control is fully turned down.
→
Ensure the connection and power of external equipment,
and the NX-100S volume control adjustment.
NX-100S only
NX-100S only
Summary of Contents for NX-100
Page 6: ...Chapter 1 BEFORE INSTALLATIONS AND SETTINGS ...
Page 12: ...Chapter 2 UNIT AND SOFTWARE INSTALLATIONS ...
Page 27: ...Chapter 3 SYSTEM SETTINGS NX 100 SETUP PROGRAM ...
Page 58: ...Chapter 4 SYSTEM SETTINGS SETTING USING BROWSER ...
Page 89: ...Chapter 5 OPERATION SETTINGS NX 100 OPERATION PROGRAM ...
Page 104: ...Chapter 6 APPENDIX ...
Page 114: ...200708 URL http www toa jp ...