background image

Page 7 of 22

 

 

                                                                  

Side

 

 

 
 

 Scene mode adjustment switch: 

Three scene modes are available: 

1.  Noisy

to the front) 

2.  Standard

in the middle

 

3.  Quiet

to the back) 

 

Standard is the default mode. 

 
 

 

 

connection wiring

 

 

 

 

Power interface: connect with 12V/1.5A power. 

 

Network interface: insert the cable to the switch. 

 

Analog audio output interface: output analog audio, connect to DVR or IP camera. 

 

External window intercom interface. 

 
 
 
 
 
 
 

Summary of Contents for N-XC65-W

Page 1: ...Page 1 of 22 USER MANUAL IP Audio Window Intercom Kit N XC65 W TOA Canada Corporation...

Page 2: ...asic Network Settings 10 2 3 1 Using the Terminal Scanning Tool 10 2 3 2 Using the Intercom built in Web Page 11 3 User defined Terminal Parameters 11 3 1 Login Web Interface 11 3 2 Network Parameters...

Page 3: ...2 4 3 Receiving Broadcasts 21 4 4 Recording 21 4 5 Engineering Mode 21 5 Troubleshooting 21 5 1 Why can t the terminal talk to others 21 5 2 Why the terminal is offline 21 5 3 Web Page is behaving abn...

Page 4: ...lead to fire or electric shock if using higher voltage Do not damage cut or twist the power cord Keep the power cable away from any heating objects and do not put heavy things on it as it may lead to...

Page 5: ...external window intercom module equipped with power input communication interface and recording output port Internal window intercom External window intercom 1 3 Features Adopt single DSP multi chann...

Page 6: ...the gooseneck microphone and fix the screw Loudspeaker amplify the audio from the external window intercom Voice broadcast button remote intercom button left When the intercom button is on blue light...

Page 7: ...2 Standard in the middle 3 Quiet to the back Standard is the default mode connection wiring Power interface connect with 12V 1 5A power Network interface insert the cable to the switch Analog audio o...

Page 8: ...crophone pick up the audio at the external window intercom module Connector to the internal window intercom module 2 Introduction 2 1 Packing List The Window intercom system includes the following acc...

Page 9: ...oseneck microphone 1 PCS 4 Power adapter 12V 1 5A 1 PCS 5 Wire binder 3 100mm 3 PCS 6 Self adhesive cable clamp 3 PCS 7 Wire terminal 1 PCS 8 Bushings cable guidance 1 PCS 9 EV cotton 1PCS 10 Installa...

Page 10: ...rcom module 3 Connect the Ethernet LAN cable to the RJ45 connector of the internal window communication module 2 3 Basic Network Settings 2 3 1 Using the Terminal Scanning Tool 1 Locate and run DevCon...

Page 11: ...IP digital window intercom The default IP address is http 192 168 1 101 Make sure you set the IP address of your computer to a correct static IP address in the same range e g 192 168 1 50 with a subn...

Page 12: ...r obtain an IP automatically from DHCP server MAC Address The physical address of the terminal This cannot be modified IP Address Terminal IP address factory default is 192 168 1 101 Subnet Mask The s...

Page 13: ...properly by sending out a tone during startup 3 4 Server Parameters The parameters have the following meanings Preferred Server The IP address of the preferred server for this intercom the factory de...

Page 14: ...tput when the host is broadcasting controlled by the server Audio Output When the broadcast is configured the audio is being output to the internal or external unit or to the internal and external uni...

Page 15: ...com Network Intercom Output Volume The volume of the network output source during intercom Internal Output Volume The output volume of the internal window intercom during intercom External Output Volu...

Page 16: ...ree parties in the conversation can hear the voices of the other two parties Disabled three party intercom cannot be initiated Whether to enable Offline Intercom When Checked when offline the terminal...

Page 17: ...m 24 hour digital recording Recording server Enter the IP address and port of the digital recording server After checking Enable Digital Recorder the system will automatically obtain it Digital record...

Page 18: ...dd the corresponding port behind the address when accessing this WEB page e g if the port is 8888 the access address will be http XXX XXX XXX XXX 8888 3 11 Language Settings You can switch the Web pag...

Page 19: ...page will be effective after restarting the device 3 13 Firmware Upgrade Click System Tools and Upgrade Firmware to enter the firmware upgrade page Click on Into Firmware Upgrade to put the device in...

Page 20: ...with the external window intercom Press the intercom button again to end the intercom the blue light goes OFF In coordination with an IP HD recording server full duplex 32K or 16K HD intercom can be a...

Page 21: ...m button and release after hearing 2 key clicks At this time all the button lights are OFF and the new volume levels are saved 5 Troubleshooting 5 1 Why can t the terminal talk to others 1 Check the i...

Page 22: ...orporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Inc 1 Harmon Plaza Suite 602 Secaucus New Jersey 07094 USA Traceability Information for Canada...

Reviews: