background image

2

1. SAFeTY pReCAUTIONS

•  Before installation or use, be sure to carefully read all the instructions in this section for correct and safe 

operation.

•  Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or 

cautions regarding safety.

•  After reading, keep this manual handy for future reference.

•  These servicing instructions are for use by qualified personnel only. Do not perform any servicing in the 

installation manual unless you are qualified to do so.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property 

damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and 

understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

WARNING

When Installing the Unit

•  Do not expose the unit to rain or an environment 

where it may be splashed by water or other liquids, 

as doing so may result in fire or electric shock. 

•  Use  the  unit  only  with  the  voltage  specified  on 

the unit. Using a voltage higher than that which is 

specified may result in fire or electric shock.

•  Do  not  cut,  kink,  otherwise  damage  nor  modify 

the power supply cord. In addition, avoid using the 

power cord in close proximity to heaters, and never 

place heavy objects -- including the unit itself -- on 

the  power  cord,  as  doing  so  may  result  in  fire  or 

electric shock. 

•  Avoid  installing  or  mounting  the  unit  in  unstable 

locations, such as on a rickety table or a slanted 

surface. Doing so may result in the unit falling 

down and causing personal injury and/or property 

damage. 

•  Install the unit only in a location that can structurally 

support  the  weight  of  the  unit  and  the  mounting 

bracket. Doing otherwise may result in the unit 

falling  down  and  causing  personal  injury  and/or 

property damage.

When the Unit is in Use

•  Should  the  following  irregularity  be  found  during 

use, immediately disconnect the power supply plug 

from the AC outlet and contact your nearest TOA 

dealer. Make no further attempt to operate the unit 

in this condition as this may cause fire or electric 

shock.

·  If  you  detect  smoke  or  a  strange  smell  coming 

from the unit

·  If water or any metallic object gets into the unit 

·  If the power supply cord is damaged (exposure of 

the core, disconnection, etc.)

·  If it is malfunctioning (no tone sounds.)

•  To prevent a fire or electric shock, never open nor 

remove  the  unit  case  as  there  are  high  voltage 

components inside the unit. Refer all servicing to 

qualified service personnel.

•  Do not insert nor drop metallic objects or flammable 

materials in the ventilation slots of the unit's cover, 

as this may result in fire or electric shock.

•  Do not touch a plug during thunder and lightning, as 

this may result in electric shock. 

CAUTION

When Installing the Unit

•  Never  plug  in  nor  remove  the  power  supply  plug 

with  wet  hands,  as  doing  so  may  cause  electric 

shock.

•  When unplugging the power supply cord, be sure to 

grasp the power supply plug; never pull on the cord 

itself.  Operating  the  unit  with  a  damaged  power 

supply cord may cause a fire or electric shock.

•  Be sure to follow the instructions below when rack-

mounting the unit. Failure to do so may cause a fire 

or personal injury.

·  Install the equipment rack on a stable, hard floor. 

Fix it with anchor bolts or take other arrangements 

to prevent it from falling down. 

Indicates a potentially hazardous situation which, if mishandled, could 

result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage.

WARNING
CAUTION

Summary of Contents for N-8000AL

Page 1: ...equipment 1 SAFETY PRECAUTIONS 2 2 General Description 4 3 Features 5 4 Nomenclature and functions 5 Front 5 Rear 5 5 INSTALLATION 6 5 1 Equipment Rack Mounting 6 5 1 1 Setting space 6 5 1 2 Mounting...

Page 2: ...of the unit and the mounting bracket Doing otherwise may result in the unit falling down and causing personal injury and or property damage When the Unit is in Use Should the following irregularity b...

Page 3: ...ou d une lectrocution Ne pas couper entortiller modifier ou endommager le cordon d alimentation En outre viter d utiliser le cordon d alimentation proximit d un radiateur et ne jamais placer d objets...

Page 4: ...acer d objets lourds sur l appareil sous peine de le faire tomber ce qui pr sente un risque de blessures corporelles et ou de dommages mat riels DESCRIPTION G N RALE L unit N 8000AL de TOA est l inter...

Page 5: ...icator STATUS Red Continuously lights while data is written to an internal storage medium FlashMemory Flashes if there is a failure 4 Power indicator POWER Green Lights when power is supplied to the u...

Page 6: ...power strips N 8000AL 50 cm 50 cm 1 m 50 cm 5 1 1 Setting space For maintenance works allow much space between the wall and Equipment rack A Temp rature ambiante lev e si l appareil est install dans...

Page 7: ...delle en fibre pour M5 2 Vis de montage en b ti 5 x 12 2 Vis taraud 3 x 14 2 Patte de montage 2 Vis de m canique 3 x 12 2 Coupleur 2 Use the optional MB 15B J hardware set when mounting 2 units Utilis...

Page 8: ...3 x 8 supplied with the N 8000AL Vis de m canique M3 x 8 fournie avec l unit N 8000AL Pied en plastique fournie avec l unit N 8000AL 5 3 Wall Mounting Montage mural The N 8000AL can be mounted on a wa...

Page 9: ...dispositif de d connexion doit tre facilement accessible Wood screw 3 5 x 20 supplied with the YC 850 Cord clamp Power supply cord Protect against disconnection Power supply plug Unlock cord clamp and...

Page 10: ...requirement that the UPS should employ the on line power system Reference Telephone interface unit 7 W rated for CE version 7 W rated for CU version 8 Port 10M 100M Switching Hub 10W Differs depending...

Page 11: ...ameter 0 4 0 65 mm AWG22 26 Solid wire Outside diameter 1 05 mm or below 6 3 Connector Connection Connect the mini clamp connector supplied with the N 8000AL to a cable using a commercially available...

Page 12: ...t corner of the last page Example Prepared in November 2004 200411 Version update information 7 Accessories Contains the N 8000 setting software program and the N 8000 series instruction manual The Se...