11
LINE OUT H C E
H C
1 2 3
E LINE/MIC IN
LINE
MIC
ON
OFF[PHANTOM]
0dB [PAD]
-20dB
LAN 52V
CTRL OUT
CTRL IN
LINK/ACT
H C
1 2 C
IP-A1AF
From external control device’s
control output terminals
From external control device’s
control input terminals
[Control input (2 channels)]
Removable terminal block (6 pins)
No-voltage make contact input
Open circuit voltage: 5 V DC
Short-circuit current: 2 mA or less
[Control output (1 channel)]
Removable terminal block (6 pins)
Open collector output
Withstand voltage: 30 V DC
Allowable current: 10 mA or less
The figure with a removable terminal plug detached.
9.3. Connections to Control Input and Output Terminals
Use the supplied removable terminal plugs (6 pins) for connection.
Connect a control line of 2 channels control input and 1 channel control output from the external
control device to the unit’s control input or control output terminal.
For connection of the removable terminal plugs, see "Removable Terminal Plug Connections" on
The following functions can be assigned to the control input and control output terminals by browser
settings:
Terminals
Assignable Functions
Control input terminals • SIP device calls
• Internal sound source broadcasts
• Local broadcasting
• Change the speaker volume (Mute or volume offset)
Control output terminals • SIP broadcast in progress output
• VMS broadcast in progress output
• Multicast broadcast in progress output
• Internal sound source broadcast in progress output
• Local broadcasting in progress output
For settings, please refer to the separate setup manual.
The latest version of the setup manual is available on the TOA DATA Library (https://www.toa-
products.com/international/).