Symptom 4. Call tone is distorted.
Test procedures
a. Prepare a pair of normal stations.
b. Make a call from one station to another by
means of continuous calling tone,
c. Confirm the occupied link number with the
LINK BUSY lamp of the HC unit. See Fig. 46.
d. Check to see if this calling tone is distorted.
e. Terminate the call by depressing C button on
the calling station,
f. Follow the procedures (b) to (e) for 16 times
(the total number of links) by using the same
stations. In this event, the LINK BUSY lamps
must light in numerical order.
Symptom 5. Conversation is normal, but paging voice is distorted.
Symptom 6. Cannot make PA paging.
Confirm the proper DIP switch setting by referring to
Installation Handbook CP-60, CP-62, CP-63 or CP-64.
— 54 —