1-2. DIP Switch Setting for the Data Receiving Unit DR-B61
The DR-B61 will control 32 relays after receiving
the data of 512 bits (16 bits × 32 words) from the
data transmitting unit. For example, word 1
covers No. 0 through No. 15 and word 2 No. 16
through No. 31 when the IN/OUT annunciation
panel is used.
One (1) word consists of 16 bits (16 relays), and
each DR unit has a 2-word capacity.
There are 32 words (WD.0 — WD.31), and any
word setting is possible including a case where all
the 16 DR units have word 0. Since the output
data (function) corresponding to each channel
varies according to the CP unit to be used, refer to
the EXPLANATION OF DATA RECEIVING UNIT
OUTPUT DATA of Installation Handbook for CP
unit when setting the word number of each DR
unit with the DIP switches of the DR unit, it is
possible to connect up to 50 DR units to one (1)
DT unit. This makes a 100-word capacity, but a
maximum number of types of word selectable is
still 32. When a system uses 50 DR units, for
example, such word arrangement is possible:
WD.0 — WD.29 × 1 each
WD.30 × 35
WD.31 × 35
30 words
35 words
35 words
totaling 100 words
— 46 —
Summary of Contents for EXES-6000
Page 1: ...TOA EXES 6000 SYSTEM TOA Corporation KOBE JAPAN...
Page 13: ...1 Voice Signal Flow Fig 15 Voice Signal Flow 10 II VOICE SIGNAL AND DIAL SIGNAL FLOWS...
Page 18: ...15 Fig 19 Voice and Dial Signal Flows 16...
Page 31: ...Fig 32 Zone Paging Signal Flow 29...
Page 32: ...Fig 33 All Call Paging Signal Flow 30...
Page 39: ...EXCHANGE A No 200 327 EXCHANGE B No 470 597 38 39...
Page 47: ...Fig 41 System Block Diagram of Data Transmitting and Receiving Units in CP 6 4 System 47...
Page 50: ...Fig 44 Contents of Data from CPU and Conversion Process into Transmitting Signal FSK 50...
Page 60: ...TOA Corporation KOBE JAPAN No 833 72 051 30 EGA09101100E Printed in Japan...