Fig. 35 shows an example where 4 stations (A) to
(D) are engaged in conference using the confer-
ence function (CL unit is necessary).
Fig. 35 Block Diagram of CL Unit
1. Example when One Station is in Conference
Supposing station (A) alone is speaking, the voice
signal flows as follows:
Timing 1. Station (A)'s mic ... HW-T ... HPF ...
Voice switch (A) ... (Voice is held)
Timing 2. Mixing point (B) ... HW-R ... Station
(B)'s speaker
Timing 3. Mixing point (C) ... HW-R ... Station
(C)'s speaker
Timing 4. Mixing point (D) ... HW-R ... Station
(D)'s speaker
— 34 —
V. PRINCIPLE OF
CONFERENCE FUNCTION
Summary of Contents for EXES-6000
Page 1: ...TOA EXES 6000 SYSTEM TOA Corporation KOBE JAPAN...
Page 13: ...1 Voice Signal Flow Fig 15 Voice Signal Flow 10 II VOICE SIGNAL AND DIAL SIGNAL FLOWS...
Page 18: ...15 Fig 19 Voice and Dial Signal Flows 16...
Page 31: ...Fig 32 Zone Paging Signal Flow 29...
Page 32: ...Fig 33 All Call Paging Signal Flow 30...
Page 39: ...EXCHANGE A No 200 327 EXCHANGE B No 470 597 38 39...
Page 47: ...Fig 41 System Block Diagram of Data Transmitting and Receiving Units in CP 6 4 System 47...
Page 50: ...Fig 44 Contents of Data from CPU and Conversion Process into Transmitting Signal FSK 50...
Page 60: ...TOA Corporation KOBE JAPAN No 833 72 051 30 EGA09101100E Printed in Japan...