PART 3. FUNCTION SELECTION FOR DATA
TRANSMITTING AND RECEIVING UNITS
8. SETTING OF CHANNEL SELECT SWITCH OF TRANSMITTING UNIT (DT-E60)
AND WORD SELECT SWITCH OF RECEIVING UNIT (DR-B61)
NOTE
1. Connect the DT-E60 and DR-B61 to Exchange correctly. (Refer
to operation manuals of DT-E60 and DR-B61).
2. Set the function select switches (DIP SWITCH) on CP-66 cor-
rectIy and be sure to enter initial programming and function
registration at programming station No.200.
3. Remove the Data Transmitting Unit (DT-E60) front cover by
pulling its handle toward you, and the channel select switches
can be seen. Set the channel select switches to enable IN/OUT
Annunciation, Calling Party Indication, etc. (Refer to 12. Expla-
nation of Data Transmitting Unit Output Data.)
4. The DT-E60 sends out 512 bit data (16 bit x 32 words) to
control relays on Data Receiving Unit (DR-B61). Therefore set
the two word select switches on DR-B61, according to necessary
output mode. SW-1 is for Relay No.1 to No.16 and SW-2 is for
Relay No.17 to No.32. See Page 51 for details.
(Refer to Explanation of Date Receiving Unit Output Channels.)
5. Connecting Cable YR-802 is used for the Rack mounting system.
Connecting Cable YR-806 is used for the Standard Cabinet
mounting system with only One (1) DT-E60 unit.
Connecting
Cable
YR-802
or
YR-806
One Pair Cable
To other DR-B61
Connecting
Cable
YR-803
To other
DT-E11
CHANNEL SELECT
Switch
To other DR-B61
WORD SELECT Switch
(SW-1, SW-2)
— 63 —
All manuals and user guides at all-guides.com