[Note]
Mark Command works only when set Fine Gain Command using.
External Control Switch LED Indication command functions only for the switch which set
External Control Switch setting.
Preset memory recall, Fader Layer recall, Console Function Key Indication command
functions only for D-2008SP (ID1).
When connecting the remote controller to the D-2008SP by way of this protocol, set the D-2008SP’s Using
port as follows:
(Refer; External Control Port Settings of the D-2000 series setting software instructions manual.)
Using Port
Serial port:
(In case of using Serial port)
Bit rate:
9,600/19,200/38,400/115,200 (Select according to the remote controller to be connected.)
or
TCP/IP port:
(In case of using TCP/IP port)
TCP Port No.:
(Set according to the remote controller to be connected.)
■
Serial Port Settings
9,600/19,200/38,400/115,200 bps, 8 bits, non-parity, stop bit: 1, no flow control
Connector: D-sub 9 pins, straight cable
Signal line: No. 2=TX; No. 3=RX; No. 5=Ground
■
TCP/IP Connection
No.
Parameter
Description (rules)
1
Connection Path
1 path
2
Data Length
Variable-length, The maximum length is 1024 bytes
3
Code Classification
Binary
4
Delivery Confirm
No handshakes at application layer
5
Resend Control
None
6
Priority Control
None
D-2008SP is a TCP server.
TCP Port is always connected.
For the purpose of connection keeping, D-2008SP performs the following behavior.
Transmitting some kind of data at least once in the last 10 seconds.
When there is the status that for send, D-2008SP transmits the contents. When there is not it,
D-2008SP transmits 0xFF only as for 1 byte.
When D-2008SP received nothing from a remote controller more than 1 minute, D-2008SP
disconnect the TCP/IP connection.