![Toa D-2008SP Operation Manual Download Page 13](http://html1.mh-extra.com/html/toa/d-2008sp/d-2008sp_operation-manual_1122873013.webp)
Digital mixer D-2000 Series
TOA Corporation
TOA Corporation
TOA Corporation
TOA Corporation
13/37
Fader Layer Recall
Recall desired fader layer.
Layers that have not been assigned to the console function keys are able to be recalled.
The D-2008SP transmits changed fader layer number after receiving this command.
C0H, 02H, <Console 1umber>, <Layer 1umber>
<Console Number>
00H - 03H
:
Console ID 1 - 4
<Layer Number>
00H - 03H
:
Layer Number 1 - 4
External Control Switch LED Indication
Set the External Control Switch’s LED indication to ON or OFF.
The D-2008SP transmits changed LED Indication status after receiving this command.
C1H, 03H, <Console 1umber>, <Key 1umber>, <O1/OFF>
<Console Number>
00H - 03H
:
Console ID 1 - 4
<Key Number>
00H - 07H
:
Function Key 1 - 8
<ON/OFF>
00H: LED OFF (Unlit)
01H: LED ON (Lit)
Auto Status 1otification Start/Stop
Set the Auto Status Notification ON or OFF without Gate Status.
F2H, 02H, 00H, <O1/OFF>
<ON/OFF>
00H: OFF (Auto Status Notification Stop)
01H: ON (Auto Status Notification Start)
Gate Status 1otification Start/Stop
Set the Gate Status Notification ON or OFF.
F2H, 02H, 01H, <O1/OFF>
<ON/OFF>
00H: OFF (Gate Status Notification Stop)
01H: ON (Gate Status Notification Start)