background image

5.  The Example  of connection of three  EX-630 exchanges

"Exchange  A"

EX-630

Terminal  board  (for  128 stations)
BX-620

"Exchange B"

EX-630

Terminal  board  (for  128 stations)

BX-620

Terminal  board  (for  128 stations)

BX-620

YR-810
for  stations

YR-801
for  Tie-line

YR-801
for  Tie-line

Terminal  board (for  128 stations)
BX-620

Terminal  board  (for  128 stations)
BX-620

"Exchange C"

EX-630

Terminal  board  (for  128 stations)
BX-620

The cables between the exchanges (4 wires x 8 links)

The cables between the exchanges (4 wires x 8 links)

"Exchange  B"

BX-620  T1

The cables between  the exchanges  (4 wires x 8 links)

YR-810
for  stations

YR-801
for  Tie-line

"Exchange  A"

BX-620  T1

YR-810

for  stations

YR-801
for  Tie-line

YR-810
for  stations

YR-801
for  Tie-line

YR-810
for  stations

YR-801
for  Tie-line

YR-810  for  stations

— 8 —

Summary of Contents for CP-64

Page 1: ...EXES 6OOO INTERCOM SYSTEM Central Processing Unit for Single Exchange System or Tie line System INSTALLATION HAND BOOK CP 64 EXES 6000 CP 64 For INTERCOMSYSTEM TOA ELECTRIC CO LTD KOBE JAPAN 133 21 11...

Page 2: ...ogramming Function Table for the System Function Table for Stations 8 9 10 11 12 13 Setting of Channel Select Switch of Transmitting Unit DT E11 and Word Select Switch of Receiving Unit DR B61 DIP Swi...

Page 3: ...NUAL 133 05 094 1A DR B61 OPERATION MANUAL 133 05 095 0 EXES 6000 CP 64 INITIAL CHECKING SHEET FOR THE SYSTEM 133 21 121 8 INTRODUCTION TO THE INSTALLATION MANUAL FOR EXES 6000 This manual forms part...

Page 4: ...all functions of the system using the Tie line function are determined by programming made in the CP 64 Composition of exchange s 2 Number of stations paging zones and links Maximum number of links wi...

Page 5: ...ut personal number 100 355 1 400 655 1 700 955 1 Numbering for paging zones All call 0 00 00 Zone 1 9 2 01 31 01 15 16 30 31 45 3 Numbering schedule for stations and paging zones 1 The first station n...

Page 6: ...nection of 2 exchanges Note 1 Any combination of tie line links between exchanges A and B is possible Note 2 Mount only one Tie line Interface unit when the number of tie line links is within 8 2 Wiri...

Page 7: ...in the CP 63 make each exchange to be of EX 1 or EX 2A or EX 2B or EX 3A or EX 3B or EX 3C type See 4 CP 64 Dip Switches for Function Selection P14 2 In the event of the tieline link not to be used t...

Page 8: ...or 128 stations BX 620 Terminal board for 128 stations BX 620 The cables between the exchanges 4 wires x 8 links YR 810 for stations Exchange A BX 620 T1 YR 801 for Tie line YR 810 for stations YR 801...

Page 9: ...stations BX 620 Terminal board for 128 stations BX 620 Exchange C EX 630 Terminal board for 128 stations BX 620 The cables between the exchanges 4 wires x 8 links The cables between the exchanges 4 w...

Page 10: ...ully charged even in the event of long hours of power failure About 4 weeks 25 C About 8 days 40 C 8 We suggest you replace the soldered button battery GB50 3FA1 115 42 031 9 with the new one accordin...

Page 11: ...of each ex change becomes the program ming station Exchange A No 200 100 Exchange B No 470 400 Exchange C No 740 700 2 lf there is any error in CMOS memory you hear calling tone instead of confirmatio...

Page 12: ...the PI unit s relay which is produced when the relay is activated through dial operation of the paging If the CP is found working normally chances are that the HC is faulty followed by the OC 3 3 Che...

Page 13: ...ink number which is indicated on the HC 64 When one Tie line Link brings up some problems which cause the system not to work properly try to find which link number is causing the problems from the ind...

Page 14: ...eady busy then the next Tie line Link is automatically used Exchange which calls Exchange which is called Tl Tie line Link Number DL Link No 2 Tie lines To TI1 TI2 3Tie lines Tl Tie line Link Number T...

Page 15: ...Programmable Station Numbering Not Activate General Purpose Control Output Capacity of General Purpose Control Not Activate Not Activate OFF Not Activate Not Activate OFF Not Activate Small Activate...

Page 16: ...es require paging function in Tie line system Otherwise the exchange with this switch off can not perform all call paging 4 Selection of Large adds 1 more digit to the number operated Programming SW E...

Page 17: ...l Digits Output Secretary Transfer Master Sub Group Hunting Paging Response Paging Priority Group Blocking of Each Group Group of Calling Party Indication Combination Paging Group Blocking Allowing Ca...

Page 18: ...tone You can select the length of time of paging pre announcement tone Programming is possible so that stations can be disconnected automatically from the speech path in the unit of Minute and the Hu...

Page 19: ...ON OFF 1 0 ON OFF 1 0 ON OFF 1 0 ON OFF 1 0 ON OFF 1 0 ON OFF 1 0 ON OFF 1 0 Secretary Station No Master Station No TransferedStation No The First Station No of the Zone The First Station No of the G...

Page 20: ...o Confirmation tone Release finished Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard Be sure to depress the key steadily 10 times 2 To release at o...

Page 21: ...inuously Called Station No OFF Touch Confirmation tone Release finished Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 10 times Be sure to depress...

Page 22: ...Allowed Station No OFF Confirmation tone Release finished Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard Be sure to depress the key steadily 10 ti...

Page 23: ...d Return 3 Re start at Step 1 when mis dialing occurs All other registrations remain valid 4 Programming is necessary only if CP DIP switch D 1 is ON Switch B 1 must be ON to employ this function NOTE...

Page 24: ...inished Confirmation tone 3 Re start at Step 1 when mis dialing occurs All other registrations remain valid NOTES 1 To allow all the stations to have this function 2 To release at one time the data pr...

Page 25: ...gle Digit Registration at Station 2 Programming at Station No 200 Function Code 54 Call to Master Station at HF 620S or HF 600S at TL 600S or HF 600S Privacy SW ON at HF 620S or HF 600S at TL 600S or...

Page 26: ...owed Station No Confirmation tone Release finished Return NOTES 1 To allow all the stations to have this function 3 Re start at Step 1 when mis dialing occurs All other registrations remain valid 4 Pr...

Page 27: ...o OFF Confirmation tone Release finished Return 3 Re start at Step 1 when mis dialing occurs 0 All other registrations remain valid Confirmation tone will be heard 4 Programming is necessary only if C...

Page 28: ...be heard Return Release finished Confirmation tone Allowed Station No Allowed Station No Release New Registration finished Confirmation tone Allowed Station No Allowed Station No New Registration STAT...

Page 29: ...nfirmation tone Release finished Return 2 To release at one time the data programmed into all the stations for this function Confirmation tone will be heard Touch Be sure to depress the key steadily 1...

Page 30: ...data programmed into all the stations for this function Confirmation tone will be heard Return Release finished Confirmation tone Release New Registration finished Confirmation tone Executive Station...

Page 31: ...curs All other registrations remain valid NOTES 1 To release at one time the data programmed into all the stations for this function Confirmation tone will be heard Return Release finished Confirmatio...

Page 32: ...Group Hunting can be made in a daisy chain method For their examples refer to the following sketch NOTES 1 To release at one time the data programmed into all the stations for this function Confirmat...

Page 33: ...Zone of No 01 to No 31 7 Zone number series of each exchange in Tie line system Exchange A No 01 15 Exchange B No 16 30 Exchange C No 31 45 6 13 PAGING ZONE FUNCTION CODE 70 ESTABLISHMENT OF EACH PAGI...

Page 34: ...rammed into all the groups for this function Confirmation tone will be heard Return New Registration finished Confirmation tone Group No First Station No Last Station No 1 8 1 6 of the Group of the Gr...

Page 35: ...roup of the Group Confirmation tone New Registration finished Return 3 When the Indication Panel belongs to only one 1 station you should write the station number in both First Sta tion No and Last St...

Page 36: ...trations remain valid Return Release finished Confirmation tone Combination Paging Zone No 90 99 Combination Paging Zone No 90 99 Release New Registration finished Confirmation tone 6 16 COMBINATION P...

Page 37: ...All other registrations remain valid Return Release finished Confirmation tone Release New Registration finished Confirmation tone Calling Group No 1 8 Calling Group No 1 8 Calling Group Called Group...

Page 38: ...ion finished Confirmation tone New Registration ALLOWING ACCESS TO PAGING ZONES Paging Zone 00 45 or Paging Group No S Combination Paging Zone 90 99 1 8 1 6 max 8 Paging Zone 00 45 or Paging Group No...

Page 39: ...istration Step 1 Hardwired Station No Programmed Station No Confirmation tone New Registration finished Release Hardwired Station No Hardwired Station No Confirmation tone Release finished Return Touc...

Page 40: ...grammed Station No Last Programmed Station No First Programmed Station No Last Hardwired Station No First Hardwired Station No First Hardwired Station No Last Hardwired Station No First Hardwired Stat...

Page 41: ...e heard Clears function group A Confirmation tone will be heard Clears function group B Confirmation tone will be heard Clears function group C Confirmation tone will be heard Clears function group D...

Page 42: ...exchange from among the followings 100 200 300 400 500 600 700 800 or 900 0 Without Calling Tone 1 Single tone 0 2 sec 2 Calling tone 0 3 sec 0 Without Paging Pre announcement Tone 1 Paging Pre announ...

Page 43: ...ontinuous Calling Tone Stations Allowed Access to All Call Stations Allowed Access to Conference Automatic Access to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make B...

Page 44: ...functions such as IN OUT Annunciation Calling Party Indication etc and replace in the Unit Refer to 12 Explanation of Data Transmitting Unit Output Data Page 48 4 The DT E11 sends out 512 bit data 16...

Page 45: ...NG AND RECEIVING UNITS Exchange Data Receiver Relay Output No WORD SELECT Switch shows the Head of a Slide Switch Note CHANNEL SELECT Switch Each channel output of DT E11 may be connected to DR B61 s...

Page 46: ...electable Make Output 64 Units Calling Party Indication Numerical Type 1 Calling Party Indication Numerical Type 2 I Calling Party Indication Lamp Type 1 Calling Party Indication Lamp Type 2 Calling P...

Page 47: ...ication YR 802 or YR 806 Exchange Data Transmitting Unit YR 803 Two wires Calling Party Display Panel with DR B61 Station numbers of Called Parties with Indicator 16 units 16 units 2 units 2 units 2 u...

Page 48: ...11 SYSTEM DIAGRAM OF DATA TRANSMITTING AND RECEIVING UNITS Tie line System Note TI 62 Tie line Interface Unit 47...

Page 49: ...EDs One contact out of 8 selectable make outputs is obtained Clear ope ration makes all 8 relays break When a station with a Display Board is called calling party number is indicated until the convers...

Page 50: ...ake Break Output Dial Operation Exchange Data Transmitter CHANNEL SELECT Switch Relay Make Relay Break XXX 000 511 512 contacts XX 00 99 100 contacts Relay Output No Each Relay Output shows Relay Cont...

Page 51: ...13 2 Channel 2 CH 2 One Shot Make Output Each Relay Output shows Relay Contact Number 50 50...

Page 52: ...hot Make Output 9 units CHANNEL SELECT Switch Example 1 4 Decimal Digits Output 2 Decimal Output 3 8 Selectable Make Output Display 8 Select Decimal X 1 9 1 9 Y 1 8 0 Clear 0 9 Bindary Negative Logic...

Page 53: ...Break WORD SELECT Switch CHANNEL SELECT Switch Binary Negative Logic 3 Example Unit No 24 Condition 3 Unit No 48 Condition 0 Binary Negative Logic 0 13 4 Channel 4 CH 4 Decimal Output 99 Units Exchang...

Page 54: ...1 Relay Make 0 Relay Break 13 5 Channel 5 CH 5 8 Selectable Make Output 64 Units CHANNEL SELECT Switch Example Unit No 8 Condition 1 Unit No 10 Condition 8 53...

Page 55: ...02 No 203 No 204 No 205 No 206 No 207 No 208 No 209 No 210 No 211 No 212 No 213 No 214 No 215 No 216 7 Segments Display of Calling Station No Waiting Station No and Total Number of Waiting Stations To...

Page 56: ...s Total Number of Station with Indications 16 stations Channel 32 stations 2 Channel No 217 No 218 No 219 No 220 No 221 No 222 No 223 No 224 No 225 No 226 No 227 No 228 No 229 No 230 No 231 No 232 d c...

Page 57: ...p Type 1 Each Calling Station or Waiting Station is shown by Each Lamp of Indication Total Number of Station with Indications 2 Stations Channel 8 Stations 4Channels Total Number of Calling Stations M...

Page 58: ...Station is shown by Each Lamp of Indication Total Number of Station with Indications 2 Stations Channel 8 Stations 4 Channels Total Number of Calling Stations Max 256 Stations Each Indication Station...

Page 59: ...tation is shown by Each Lamp of Indication Total Number of Station with Indications 2 Stations Channel 8 Stations 4 Channels Total Number of Calling Stations Max 256 Stations Each Indication Station N...

Page 60: ...or Waiting Station is shown by Each Lamp of Indication Total Number of Station with Indications 2 Stations Channel 8 Stations 4 Channels Total Number of Calling Stations 256 Stations Each Indication...

Page 61: ...p on A person No 1006 registers his Personal Number at the station No 216 then the Relay contact No 216 turns into Make Each Relay Output shows Station No of Person s Destina tion Each Relay Output sh...

Page 62: ...6 then the Relay contact No 216 turns into Make Each Relay Output shows Station No of Person s Destina tion 13 13 Channel 13 CH 13 Destination Indication 2 Dial Operation Registration of Personal Numb...

Page 63: ...3 digits xxx of Personal Number 13 14 Channel 14 CH 14 In Out Annunciation 1 504 persons Dial Operation Personal Number Registration Personal Number Cancellation Relay Make XXX 000 503 504 contacts Re...

Page 64: ...tion 2 496 persons Dial Operation Personal Number Registration Personal Number Cancellation Relay Make XXX 000 499 500 Contacts Relay Break Relay Output No Each Relay Output shows last 3 digits xxx of...

Page 65: ...TOA ELECTRIC CO LTD KOBE JAPAN...