Operation Mode
Constant Mode
Constant mode offers continuous lighting intensity control. Lighting intensity is controlled
using constant current technique. Brightness can be adjusted from fully off to fully on in the
range of 0 – 255.
Strobe Mode
Strobe mode provides short interval triggering for applications that require high intensity and
high precision. An input trigger signal will turn on the lighting output based on pre-set delay
and duration parameters.
There are 4 adjustable strobe parameters available:
Strobe Delay = Delay time between the external input signal and the lighting output
Strobe Width = Duration of the lighting’s turn on time
Output Delay = Delay time between the external input signal and the external output signal
Output Width = Duration of the external output signal’s turn on time
Parameter timings are in the range of 0-9999 which is equivalent to 0-99.99ms (in step of 10us)
External Trigger
Lighting Strobe
Camera Output
Strobe Delay
Strobe Width
Output Delay Output Width