TMS Lite
LC-18-SQ-4CH-A1 LIGHTING CONTROLLER UNIT
25
5. Read from Slave
Command List
Command Code (YY)
Command Description
Return
Data (ZZZZ)
No. of Byte
RM
Read Channel Mode
0 = Constant
1 = Strobe
2 = Trigger
1
Type: Global
Tx = @0xRM{}
Rx = @0xRM{Z}
RR
Read Current Multiplier
1-10
2
Type: Individual
Tx = @0xRR{}
Rx = @0xRR{ZZ}
RI
Read Intensity
0 – 255
3
Type: Individual
Tx = @0xRI{}
Rx = @0xRI{ZZZ}
RW
Read Strobe Width
0 – 9999 (99.99ms)
4
Type: Individual
Tx = @0xRW{}
Rx = @0xRW{ZZZZ}
RY
Read Output Delay
0 – 9999 (99.99ms)
4
Type: Global
Tx = @0xRY{}
Rx = @0xRD{ZZZZ}
RH
Read Output Width
0 – 9999 (99.99ms)
4
Type: Global
Tx = @0xRH{}
Rx = @0xRH{ZZZZ}
RN
Read No. of Frame
1-10
2
Type: Global
Tx = @0xRN{}
Rx = @0xRN{ZZ}
RE
Read Frame Width
0 – 9999 (99.99ms)
4
Type: Global
Tx = @0xRE{}
Rx = @0xRE{ZZZZ}
RF
Read Frame
Frame Value Z: 0-F
1
Type: Global
Frame No X: 0-9
Tx = @0xRF{X}
Rx = @0xRF{Z}
RV
Read Version
WXYZ (W.X.Y.Z)
0
Type: Global
Tx = @0xRV{}
Rx = @0xRV{W.X.Y.Z)
*Remark: For global type function, set channel no. to any valid number (1-4).