2.To remove the winding stem
(1) set the winding stem to normal position.
(2) While pushing the indented portion of the arrow,
pull out the winding stem.
Push
3.How to attach hands
Place the movement directly on a flat metal plate or the like and press in the hands.
*install the hour , minute and second hands at the "12"o'clock position.
*Install the 24 hour indicator at the "24" position.
*Install the dual time of 12 hour regulator and dual time of 60 minute regulator hands at the "12" and "60"
position respectively.
[ Reference ]
The power of press hands
Minute & Hour Hands
< 5kg
Second Hand
< 5kg
24 hour indicator
< 3kg
Dual time of 12 hour regulator hand
< 3kg
Dual time of 60 minute regulator hand
< 3kg
SII Products
7
TECHNICAL GUIDE
Version-01