T

EMPERATURE

 

 

To check the temperature of the Mozart One, tap the address set button and the 7-segment display will show 
the temperature (e.g. 28 °C): 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 

 

Appendix

 

 
RDM

 

F

UNCTIONALITY

 

 

Mozart Drives have RDM functionality.  Below are the RDM functions available in these devices.  TMB has 
many options for RDM control of your devices:  ProPlex RDMigo and IQ RDM Manager Software; ProPlex 
Striker; and ProPlex MasterFade.  Additionally, ProPlex RDM Opto-Splitters and the ProPlex IQ product 
range offer many means of RDM over DMX data distribution. 
 

 

Main 

Voltage (V) 

Current (A) 

Mode 

Present value 

Present value 

DMX address 

Highest value 

Highest value 

RDM version 

Lowest value 

Lowest value 

Software version 

 

 

 

 

G

ENERAL 

M

AINTENANCE

 

 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage and 
environment are contributing factors in determining frequency.  As a general rule, fixtures should be 
cleaned at least twice a month.  Dust build up reduces light output performance and can cause 
overheating.  This can lead to reduced lamp life and increased mechanical wear. Be sure to disconnect 
power to the fixture before conducting maintenance. 
 
Unplug fixture from power.  Use a vacuum or air compressor and a soft brush to remove dust 
collected on external vents and internal components.  Clean all glass when the fixture is cold with a mild 
solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to 
the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they 
are free of haze and lint. 

Summary of Contents for Solaris Mozart One

Page 1: ...Mozart One User Manual TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com ...

Page 2: ...pon receipt of the fixture carefully unpack the carton and check the contents to ensure that all parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to ...

Page 3: ... the unit immediately Repairs must be carried out by trained authroized personnel Contact the nearest authorized technical assistance center Only OEM spare parts should be used Do not connect the device to a dimmer pack Make sure the 3 conductor Power Data cord is never crimped or damaged Never disconnect 3 conductor Power Data cord by pulling or tugging on the cord Avoid direct eye exposure to th...

Page 4: ...re where it will be exposed to moisture high humidity extreme temperatures or restricted ventilation Setup A DMX data link is needed to run light shows of one or more fixtures using a DMX 512 lighting console The combined number of channels required by all of the fixtures on the DMX data link will determine the number of fixtures the DMX data link can support Important Fixtures on a DMX data link ...

Page 5: ...unded or shorted to the shield or each other SETTING UP A DMX SERIAL LINK 1 Connect the male 5 pin connector side of the DMX cable to the output female 5 pin connector of the DMX console 2 Connect the opposite end of the cable female to the input connector of the Mozart Drive consisting of a male 5 pin connector 3 Proceed to connect from the Drive output as stated above to the input of the followi...

Page 6: ...rotocol INTERNAL ADDRESS SET The external Mozart Drive has a user definable DMX starting address adjusted via RDM Additionally each Mozart One also has an independent ID that will indicate its position in the DMX universe Each connected Mozart One can be given an indpedent ID number or they can all be the same up to 10 fixtures linked in Regular mode 5 fixtures linked in HiPower Mode Follow these ...

Page 7: ...peat until the desired ID number is shown on the 7 segment display Using DMX 1 for a starting address on the Mozart Drive following are examples of the Mozart One fixture ID DMX CH FIXTURE ID 1 PIX 1 W 1 2 W 2 3 W 3 DMX CH FIXTURE ID 1 PIX 1 2 3 R G B 1 4 5 6 R G B 2 7 8 9 R G B 3 DMX CH FIXTURE ID 1 PIX 1 2 3 4 R G B W 1 5 6 7 8 R G B W 2 9 10 11 12 R G B W 3 Continue as necessary ...

Page 8: ...re version GENERAL MAINTENANCE To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be ...

Page 9: ...ir of the Product in the field and any associated labor charges must be authorized in advance by TMB Freight costs on warranty repairs are split 50 50 Customer pays to ship defective product to TMB TMB pays to ship repaired product ground freight back to Customer This warranty DOES NOT cover consequential damages or costs of any kind A Return Merchandise Authorization RMA Number must be obtained f...

Page 10: ... fixture 1 3 4 Color LEDs RGBW Color Mode White RGB RGBW Refresh rate 1200 HZ Intensity Control 8 bit Control Mozart Drive DC power 48 VDC Power Consumption 20 W or 40 W HiPower mode Cooling Convection IP Rating IP65 Operating Temperature 20 C 40 C Control Power Connectors In Out Amphenol M12 Dimensions HxWxD 4 6 x 5 6 x 6 3 in 118 x 141 x 160 mm Weight 3 74 lb 1 7 kg Inches mm ...

Page 11: ...in XLR female socket DMX output Mozart One 10 max 5 max high power mode Power IN 100 240 VAC Power OUT Mozart One 48 VDC Power Consumption 200 W max 10 Mozart Ones standard power Cooling Convection IP Rating IP20 Operating Temperature 4 to 104 F 20 to 40 C Control Power Connectors In Out Amphenol M12 Dimensions w yoke HxWxD 5 3 x 7 9 x 10 7 in 135 x 202 x 272 mm Dimensions w o yoke HxWxD 3 4 x 7 7...