F

REQUENCY 

S

ETTINGS

 

 

Depending on location, change the Default Frequency setting to match the mains power (e.g. North America 
should be set at 60Hz). Proper frequency setting will ensure minimum number of visible artifacts when using 
Solaris on camera. 

 

S

AFETY 

I

NSTRUCTIONS

 

 
 

 
 
 

 

 

 

Please keep this User Guide for future reference.  If unit is sold to another user, make sure they also 
receive this instruction booklet. 

 

Ensure fixture and Mozart Drive are connected to proper voltage, and that line voltage is not higher than 
that stated on the fixture. 

 

Make sure there are no flammable materials close to the unit while operating. 

 

Always disconnect from the power source before servicing or fuse replacement.  Always use the fuse 
specified in this manual.. 

 

Always use a safety cable when hanging fixture overhead. 

 

Maximum ambient temperature (Ta) is 40°C (104°F). Do not operate fixture at temperatures above this 
rating.  

 

In the event of a serious operating problem, stop using the unit immediately.  Repairs must be carried 
out by  trained, authroized personnel.  Contact the nearest authorized technical assistance center.  Only 
OEM spare parts should be used. 

 

Do not connect the device to a dimmer pack. 

 

Make sure the 3-conductor Power+Data cord is never crimped or damaged. 

 

Never disconnect 3-conductor Power+Data cord by pulling or tugging on the cord. 

 

Avoid direct eye exposure to the light source during operation. 

 

Caution!  There are no user serviceable parts inside the unit.  Do not open the housing or attempt 
any repairs yourself.  In the unlikely event your unit may require service, please contact your 
distributor. 

 

 
 

 
F

USE 

R

EPLACEMENT

 

 

The Mozart Drive PortableMount uses a 4A, 250V, slow-blow, 5x20mm (0.2x0.8 in.) fuse.  Mozart One 
fixtures have no fuse.  To replace fuse: 

1.  With a screwDriver turn the fuse cap counter-clockwise to remove fuse cap with fuse. 
2.  Replace fuse attached to fuse cap. 
3.  Reinsert fuse cap with new fuse and tighten clockwise. 

 

 
 
 

Please read these instructions carefully.  This user guide 
contains important information about the installation, usage 
and maintenance of this product.

 

 

Disconnect the power cord before replacing a 
fuse and always replace with the same type fuse. 

 

Summary of Contents for Solaris Mozart One

Page 1: ...Mozart One User Manual TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com ...

Page 2: ...pon receipt of the fixture carefully unpack the carton and check the contents to ensure that all parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to ...

Page 3: ... the unit immediately Repairs must be carried out by trained authroized personnel Contact the nearest authorized technical assistance center Only OEM spare parts should be used Do not connect the device to a dimmer pack Make sure the 3 conductor Power Data cord is never crimped or damaged Never disconnect 3 conductor Power Data cord by pulling or tugging on the cord Avoid direct eye exposure to th...

Page 4: ...re where it will be exposed to moisture high humidity extreme temperatures or restricted ventilation Setup A DMX data link is needed to run light shows of one or more fixtures using a DMX 512 lighting console The combined number of channels required by all of the fixtures on the DMX data link will determine the number of fixtures the DMX data link can support Important Fixtures on a DMX data link ...

Page 5: ...unded or shorted to the shield or each other SETTING UP A DMX SERIAL LINK 1 Connect the male 5 pin connector side of the DMX cable to the output female 5 pin connector of the DMX console 2 Connect the opposite end of the cable female to the input connector of the Mozart Drive consisting of a male 5 pin connector 3 Proceed to connect from the Drive output as stated above to the input of the followi...

Page 6: ...rotocol INTERNAL ADDRESS SET The external Mozart Drive has a user definable DMX starting address adjusted via RDM Additionally each Mozart One also has an independent ID that will indicate its position in the DMX universe Each connected Mozart One can be given an indpedent ID number or they can all be the same up to 10 fixtures linked in Regular mode 5 fixtures linked in HiPower Mode Follow these ...

Page 7: ...peat until the desired ID number is shown on the 7 segment display Using DMX 1 for a starting address on the Mozart Drive following are examples of the Mozart One fixture ID DMX CH FIXTURE ID 1 PIX 1 W 1 2 W 2 3 W 3 DMX CH FIXTURE ID 1 PIX 1 2 3 R G B 1 4 5 6 R G B 2 7 8 9 R G B 3 DMX CH FIXTURE ID 1 PIX 1 2 3 4 R G B W 1 5 6 7 8 R G B W 2 9 10 11 12 R G B W 3 Continue as necessary ...

Page 8: ...re version GENERAL MAINTENANCE To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be ...

Page 9: ...ir of the Product in the field and any associated labor charges must be authorized in advance by TMB Freight costs on warranty repairs are split 50 50 Customer pays to ship defective product to TMB TMB pays to ship repaired product ground freight back to Customer This warranty DOES NOT cover consequential damages or costs of any kind A Return Merchandise Authorization RMA Number must be obtained f...

Page 10: ... fixture 1 3 4 Color LEDs RGBW Color Mode White RGB RGBW Refresh rate 1200 HZ Intensity Control 8 bit Control Mozart Drive DC power 48 VDC Power Consumption 20 W or 40 W HiPower mode Cooling Convection IP Rating IP65 Operating Temperature 20 C 40 C Control Power Connectors In Out Amphenol M12 Dimensions HxWxD 4 6 x 5 6 x 6 3 in 118 x 141 x 160 mm Weight 3 74 lb 1 7 kg Inches mm ...

Page 11: ...in XLR female socket DMX output Mozart One 10 max 5 max high power mode Power IN 100 240 VAC Power OUT Mozart One 48 VDC Power Consumption 200 W max 10 Mozart Ones standard power Cooling Convection IP Rating IP20 Operating Temperature 4 to 104 F 20 to 40 C Control Power Connectors In Out Amphenol M12 Dimensions w yoke HxWxD 5 3 x 7 9 x 10 7 in 135 x 202 x 272 mm Dimensions w o yoke HxWxD 3 4 x 7 7...