ENGLISH
ENGLISH
23
Press “Menu/confirm” and use UP and DOWN to set the number of days you wish, between 00 and 40. That
is preset at 30 days. Press “Menu/confirm” to confirm.
Button “UP”
Button “DOWN”
Button “MENU”
Button “MENU”
11. Maximum days between regenerations H- :
Press the button DOWN, the screen will show H- (maximum days between regenerations).
These are number of days that if there is no water consumption after the days we have scheduled, there will
be a maintenance regeneration.
Table 2. Regeneration time for each cycle (using standard resine as reference) at 3 bars entry pressure.
Regeneration times according to liters of resin in the bottle
7
14
20
22
30
35
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
Liters of
resin
Bottle
First cycle:
backwash
Programa 2
25 min.
30 min.
30 min.
30 min.
45 min.
45 min.
Second cycle:
aspiration of brine
Programa 3
1 min.
2 min.
3 min.
3 min.
4 min.
4 min.
Third cycle:
brine load
Programa 4
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
Fourth cycle:
Quick wash
Programa 5
07x17
10x17
08x35
08x35
10x35
10x35
Injector according
to bottle Ø
Pink
White
Yellow
Yellow
White
White