background image

 

172-65460MA-04  (JH7.5R-X)    20  Oct  2020

 

14

 

Product Warranty 

 

1.  Warranty Period 

One year following product delivery. 

 
2.  Warranty Coverage 

TLV CO., LTD. warrants this product to the original purchaser to be free 
from defective materials and workmanship. Under this warranty, the 
product will be repaired or replaced at our option, without charge for parts 
or labor. 

 
3.  This product warranty will not apply to cosmetic defects, nor to any 

product whose exterior has been damaged or defaced; nor does it apply 
in the following cases: 

1)  Malfunctions due to improper installation, use, handling, etc., by other 

than TLV CO., LTD. authorized service representatives. 

2)  Malfunctions due to dirt, scale, rust, etc. 

3)  Malfunctions due to improper disassembly and reassembly, or 

inadequate inspection and maintenance by other than TLV CO., LTD. 
authorized service representatives. 

4)  Malfunctions due to disasters or forces of nature. 

5)  Accidents or malfunctions due to any other cause beyond the control 

of TLV CO., LTD. 

 
4.  Under no circumstances will TLV CO., LTD. be liable for consequential 

economic loss damage or consequential damage to property. 

 

*    *    *    *    *    *    *

 

 

For Service or Technical Assistance: 

Contact your TLV

 

representative or your regional

 

TLV office. 

   
 

Manufacturer 

 

881 Nagasuna, Noguchi 
Kakogawa, Hyogo 675-8511, JAPAN 
Tel: 81-(0)79-427-1800 
 

 

Summary of Contents for JH7.5R-X

Page 1: ...172 65460MA 04 JH7 5R X 20 October 2020 Free Float Steam Trap with X element JH7 5R X Copyright 2020 by TLV CO LTD All rights reserved ...

Page 2: ...is steam trap is also of a revolutionary design featuring an integral air vent that employs a high performance X element The X element is very sensitive to changes in temperature and responds with great accuracy As a result air and the large quantities of condensate created immediately after the start up of operation are quickly discharged thereby greatly reducing start up time and also proving us...

Page 3: ...oses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING NEVER apply direct heat to the float The float may explode due to increased internal pressure causing accidents leading to serious injury or damage to property and equipment CAUTION Install...

Page 4: ... recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other inju...

Page 5: ... back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow of condensate is not o...

Page 6: ...lows for the rapid discharge of the air After the air is discharged and steam contacts the X element the temperature will increase causeing the air vent valve A to close 4 Discharge of Large Quantities of Condensate Increases in the condensate inflow rate cause the condensate level in the trap to rise The float consequently rises and enlarges the opening of the orifice B allowing more condensate t...

Page 7: ...l Maximum Allowable Temperature TMA Maximum Allowable Pressure Maximum Operating Temperature Nominal Diameter Maximum Differential Pressure Valve No Production Lot No Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when there are...

Page 8: ...scharge of fluids CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Ins...

Page 9: ...products or losses due to steam leakage Normal Condensate is discharged continuously together with flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes no noise and the surface temperature of the trap is low Blowing Live steam continually flows from the...

Page 10: ...w gasket coat surfaces with anti seize Detaching Reattaching the Cover and its Components Part During Disassembly During Reassembly Cover Nut Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Cover Remove by lifting up and off Make sure there are no pieces of the old gasket left on the sealing surfaces of the body and cover align the arrows on the...

Page 11: ...t being careful not to scratch the polished surface Orifice Plug Remove with a box wrench Consult the table of tightening torques and tighten to the proper torque Orifice Plug Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket coat surfaces with anti seize Orifice Remove with a box wrench Consult the table of tightening torques and tighten to the proper torque Orifice Ga...

Page 12: ...172 65460MA 04 JH7 5R X 20 Oct 2020 11 Exploded View ...

Page 13: ...e affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads 5 Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down 6 Screw the plug holder by hand into the product body while making sure that the gasket remains tightly affixed to the ce...

Page 14: ...e maximum specified pressure or whether there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks from the outlet blowing steam leakage Build up on the seating surface of the orifice or rust and scale build up beneath the float Clean parts Scratches on the orifice Replace with a new orifice The ...

Page 15: ...roper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate inspection and maintenance by other than TLV CO LTD authorized service representatives 4 Malfunctions due to disasters or forces of nature 5 Accidents or malfunctions due to any other cause ...

Page 16: ...MA 04 JH7 5R X 20 Oct 2020 15 Options The options shown below are available for this product on request Please compare with the product you received Options for Area A standard with drain plug Without Drain Plug ...

Reviews: