172-65459MA-04 (JH7.2R-P) 14 Jul 2015
6
Specifications
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
DO NOT use this product in excess of the maximum operating pressure
differential; such use could make discharge impossible (blocked).
CAUTION
Use only under conditions in which no freeze-up will occur. Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
CAUTION
Refer to the product nameplate for detailed specifications.
Model
Maximum Allowable
Temperature (TMA)*
Maximum Allowable
Pressure*
Nominal Diameter
Maximum Differential
Pressure
Production Lot No.
Valve No.**
Maximum Operating
Temperature
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL
DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
** Valve No. is displayed for products with options. This item is omitted from the nameplate when there are
no options.
Configuration
No. Name
M* R* F* No. Name
M* R*
1 Body
10 Cover Gasket
2 Cover
11 Cover Bolt
3 Float
12 Cover Nut
4 Orifice
13 Nameplate
5 Orifice Gasket
14 Flange / Socket
6 Orifice Plug
15 Cover Plug Gasket
7 Orifice Plug Gasket
16 Cover Plug
8 Screen
17 Drain Plug Gasket
9 Screen Holder
18 Drain Plug
* Replacement parts are available only in the following kits:
M = Maintenance Kit, R = Repair Kit, F = Float