background image

 

172-65483MA-03(JH3S-X / JH5SL-X)  31 Jul 2017 

2

 

Safety Considerations 

  Read this section carefully before use and be sure to follow the instructions. 

  Installation, inspection, maintenance, repairs, disassembly, adjustment and valve 

opening/closing should be carried out only by trained maintenance personnel. 

  The precautions listed in this manual are designed to ensure safety and prevent 

equipment damage and personal injury. For situations that may occur as a result 
of erroneous handling, three different types of cautionary items are used to 
indicate the degree of urgency and the scale of potential damage and danger: 
DANGER, WARNING and CAUTION. 

  The three types of cautionary items above are very important for safety: be sure to 

observe all of them as they relate to installation, use, maintenance, and repair. 
Furthermore, TLV accepts no responsibility for any accidents or damage occurring 
as a result of failure to observe these precautions. 

Symbols 

 

Indicates a DANGER, WARNING or CAUTION item. 

 

DANGER 

 

Indicates an urgent situation which poses a threat of death or 
serious injury 

 

WARNING 

 

Indicates that there is a potential threat of death or serious injury 

 

CAUTION 

 

Indicates that there is a possibility of injury or equipment / product 
damage 

 
 

 

WARNING 

 

NEVER apply direct heat to the float. 

The float may explode due to increased internal pressure, causing 
accidents leading to serious injury or damage to property and 
equipment. 

 

CAUTION 

 

Install properly and DO NOT use this product outside the 
recommended operating pressure, temperature and other 
specification ranges. 

Improper use may result in such hazards as damage to the product 
or malfunctions that may lead to serious accidents. Local 
regulations may restrict the use of this product to below the 
conditions quoted. 

 

DO NOT use this product in excess of the maximum operating 
pressure differential. 

Such use could make discharge impossible (blocked).

 

 

Take measures to prevent people from coming into direct 
contact with product outlets. 

Failure to do so may result in burns or other injury from the 
discharge of fluids.

 

 

 

 

When disassembling or removing the product, wait until the 
internal pressure equals atmospheric pressure and the surface 
of the product has cooled to room temperature

Disassembling or removing the product when it is hot or under 
pressure may lead to discharge of fluids, causing burns, other 
injuries or damage.

 

 

Safety considerations continued on next page. 

Summary of Contents for JH3S-X

Page 1: ...172 65483MA 03 JH3S X JH5SL X 31 July 2017 Free Float Steam Trap with X element JH3S X JH5SL X Copyright 2017 by TLV CO LTD All rights reserved ...

Page 2: ...ture and responds with great accuracy As a result air and the large quantities of condensate created immediately after the start up of operation are quickly discharged thereby greatly reducing start up time and also proving useful in valve operation bypass blowdown labor saving The X element is also sensitive to hot air during operation responding quickly and thus preventing the occurrence of air ...

Page 3: ...potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING NEVER apply direct heat to the float The float may explode due to increased internal pressure causing accidents leading to serious injury or damage to property and equipment CAUTION Install properly and DO NOT use this product outside the recommended operating pre...

Page 4: ...n damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other injury Use only under conditions in which no water hammer will occur The impact of water hammer may damage the product leading to fluid discharge which may...

Page 5: ... to back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow of condensate is no...

Page 6: ... condensate level causes the float to rise due to buoyancy opening the orifice B and allowing condensate to be discharged 3 Hot Air Discharge Should hot air flow into the trap with the steam during normal operation the temperature of the X element drops causing it to momentarily contract and open the air vent valve A which allows for the rapid discharge of the air After the air is discharged and s...

Page 7: ... other injury CAUTION Refer to the product nameplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Nominal Diameter Maximum Differential Pressure Production Lot No Valve No Maximum Operating Temperature Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displ...

Page 8: ... kit R repair kit F float No Name M R F 1 Body 2 Cover 3 Float 4 Orifice 5 Orifice Gasket 6 Orifice Plug 7 Orifice Plug Gasket 8 Float Cover 9 Screen 10 Flange Socket 11 Cover Bolt 12 Cover Nut 13 Cover Gasket 14 Connector 15 Connector Gasket 16 X element Guide 17 X element 18 Spring Clip 19 Air Vent Valve Seat 20 Name Plate ...

Page 9: ...mbly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product so the arrow on the body is pointing in the direction of flo...

Page 10: ... flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes no noise and the surface temperature of the trap is low Blowing Live steam continually flows from the outlet and there is a continuous metallic sound Steam Leakage Live steam is discharged through th...

Page 11: ...a new gasket coat surfaces with anti seize Detaching Reattaching the Cover Part During Disassembly During Reassembly Cover Nut Cover Bolt Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Cover Remove by lifting up and off Make sure there are no pieces of the old gasket left on the sealing surfaces of the body and cover then reattach lining up the...

Page 12: ...ket Remove the gasket and clean sealing surfaces Replace with a new gasket coat surfaces with anti seize Orifice Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Orifice Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket coat surfaces with anti seize Table of Tightening Torques Part Name Torque Distance Across Flats N m...

Page 13: ...5SL X 31 Jul 2017 12 Exploded View JH3S X Float Cover Screen Float Body Orifice Gasket Orifice Orifice Plug Gasket Orifice Plug Cover Gasket X element Guide Air Vent Valve Seat X element Spring Clip Connector Cover Cover Bolt ...

Page 14: ...1 Jul 2017 13 JH5SL X X element Guide Air Vent Valve Seat Cover Nut Cover Float Cover Screen Float Cover Bolt Body Orifice Gasket Orifice Orifice Plug Gasket Orifice Plug Connector Connector Gasket X element Spring Clip Cover Gasket ...

Page 15: ... the gasket onto the center of the gasket surface of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down Screw the plug holder by hand...

Page 16: ...e trap operating pressure exceeds the maximum specified pressure or there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks from the outlet blowing steam leakage Build up on the seating surface of the orifice or rust and scale build up beneath the float Clean parts Scratches on the orifice Rep...

Page 17: ... to improper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate inspection and maintenance by other than TLV CO LTD authorized service representatives 4 Malfunctions due to disasters or forces of nature 5 Accidents or malfunctions due to any other...

Page 18: ...closed position 2 Before operating the lock release valve examine the trap outlet and confirm that the trap is functioning properly 3 Operate the lock release valve as follows tools required flat head screwdriver Open Valve Insert the screwdriver into the slot on the top of the element retainer and slowly turn clockwise Do not turn the element retainer past the point at which it stops See charts b...

Page 19: ...kg cm 2 Differential Pressure kg cm 2 Discharge Capacity kg h Discharge Capacity liter min Differential Pressure MPa Differential Pressure MPa Discharge Capacity lb h Discharge Capacity scfm Differential Pressure psi Differential Pressure psi Capacities are equivalent capacities of standard air 20 C 68 F under atmospheric pressure ...

Page 20: ...bottom of the gland case See the above table to determine the amount of steam discharge Close Valve Slowly turn clockwise Do not continue turning the needle valve past the point at which it stops 3 If steam should leak from the gland retainer nut or gland case it can be stopped by further tightening the gland retainer nut Do not over tighten otherwise the needle valve may seize and become unworkab...

Reviews: