172-65132MA-07 (JX Series) 16 Feb 2022
9
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or malfunctions
that may lead to serious accidents. Local regulations may restrict the use of this
product to below the conditions quoted.
Use hoisting equipment for heavy objects (weighing approximately 20 kg or
more).
Failure to do so may result in back strain or other injury if the object should fall.
Take measures to prevent people from coming into direct contact with product
outlets.
Failure to do so may result in burns or other injury from the discharge of fluids.
Do not use excessive force when connecting threaded pipes to the product.
Over-tightening may cause breakage leading to fluid discharge, which may cause
burns or other injury.
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
1. Before installation, be sure to remove all protective seals.
2. Before installing the product, blow out the inlet piping to remove any piping scraps,
dirt and oil. Close the inlet valve after blowdown.
3. Install the product so that the arrow on the body is pointing in the direction of flow.
4. The product should be inclined no more than 5° horizontally and front-to-back.
5. Install a condensate outlet valve and outlet piping.
6. Open the inlet and outlet valves and ensure that the product functions properly.
If there is a problem, determine the cause using the “Troubleshooting” section in this
manual.
Tolerance Angle for Installation: 5°
Make sure the product is installed with the raised TLV lettering on the body horizontal.
CAUTION