172-65143M-04 (BB1N·BBF1N) 7 Oct 2021
9
Disassembly/Reassembly of the Valve Unit Gland Section
Part
During Disassembly
During Reassembly
During Inspections
Holder Screw
Remove with a hex key
For stainless steel valve
bodies, coat the threaded
portions with anti-seize
and tighten to the proper
torque
—
Holder
Remove with a socket
wrench
For stainless steel valve
bodies, coat the threaded
portions with anti-seize
and tighten to the proper
torque
—
Guide Bushing
Remove guide bushing
Reinsert guide bushing
Check for wear
Seal
Remove the seal
Use a new part
—
Stem Packing
Remove the packing
Use a new part
—
Spindle
Remove the spindle
Reinsert the spindle
Check both faces for
deformation. Check
for wear, damage and
corrosion
Valve Shaft
Remove the valve shaft
Reinsert the valve shaft
Check for wear or
deformation
Gland Seat
Remove the gland seat
Use a new part
—
Washer
Remove the washer
Reinsert the washer
Check for damage or
deformation
Belleville
Washer
Remove the Belleville
washer
Reinsert the Belleville
washer, referring to the
drawing on the following
page for proper orientation
Check for damage or
deformation
Gasket
Remove the gasket and
clean sealing surfaces
Replace with a new gasket
if damaged or deformed,
referring to the drawing on
the following page for
proper orientation.
—
(1 N·m
10 kg·cm)
NOTE: 1. Reassemble the gland section after reassembling the valve section (see the
Disassembly/Reassembly of the Valve Section in the Disassembly/Reassembly
section).
2. When reinserting the spindle and valve shaft into the ball:
for the screwed model, finger-tighten the inlet union; for the flanged model, finger-
tighten the flange bolt. This serves as preparation for centering the ball.
When reassembly is completed, tighten the valve holder.