background image

  
 

Press “Note >“ once. After that, keep the “S” key pressed and tap 
the “Note >” key several times, until this indicator appears on the 
display: 

Confirm the operation by pressing key “E”“.  

You will see this indicator. Here you can enter a concert pitch you 
want to start your application. In this example we leave 440 Hz. 

 

Press the “E“ key. The standard pitch will be stored to the 
instrument program, the Tuning Set enters the input mode. Here 
you can assign a cent value and a partional to every tone. In this 
example we skip this option and press the button “E” second times. 

 

At this point, setting the option “Hist.Temperament“ to “on“, will 
allow you to select an historical temperament before entering the 
tuning mode (not otherwise). Press the ”E“ key 

Now you enter the real parameters of the thermosensor: 

Using the “func“ keys, enter the room temperature offset at which 
you expect the tuning of your music instrument.The concert pitch 
(440 Hz in this example), you entered for this instrumentprogram, is 
assigned to this room temperature offset. Simple description: If the 
room temperature reaches the value entered here (20°C in this 
example), the cent correction value of the sensor becomes zero. 

Press key “E” again. Using the “func“ keys, enter the cent rate 
value, corresponding to the pitch difference of your music 
instrument when the room temperature rises by 1 degree 
centigrade. For example 3.2 cent for air-pipes 

 

To confirm press key “E“.  

You instrument program will now be stored.  

 

 

3. How to call your instrument program 

In order to use the instrument program with the thermosensor, with 
the menu control find this indicaton on the display. 

 

Press key “E“. 

If you have entered a cent-rate not equal to zero in your instrument program, you receive now a 
walking indikation “Thermo Cents !!! go ahaed with key S + F” 

Press key “E“again. You receive this indication. On the left side the 
actual room temperature and on the right side the cent correction 
value of the sensor will be indicated. 

Press key “E“again. The device is now in the tune-mode. Remark: 
The cents which are inicated here does nor relate to the 
thermosensor. They will be added to this. Approx. every 30 secons 
the thermo cents will be updated by the sensor. 

  * 
THERMO_________14 

_a_1          P14 
440.00

 

 

_a_1   0.0

 

  S14 

         1   --- 

Hist.Temperament 
off 

th.sensor rate 
3.2 cent/celsi 

19.0°C -3.2 cent 

_a_1   0.0   T14 

440.00

?  

1    --- 

store with     E 
back with  <  > 

th.sensor offset 
20.0 deg.centig 

ENTER INST.  214 
THERMO________14 

TUNE         214 
THERMO________14 

Reviews: