TJM Pro Series Twin Compressor: Installation and User Manual
For product warranty please refer to our website www.tjm.com.au
File: F-31070
Page 22 of 23
23/02/2021
7.
Maintenance
Always ensure that the pressure in the compressor has been discharged before commencing.
Routine Maintenance
o
Periodically inspect and replace the air filter. Blocked air filters significantly reduce compressor
performance. Never run the compressor without a filter
–
this will reduce the life of the compressor.
o
Periodically check fittings and airlines for leaks.
o
Periodically inspect mount bolts to ensure that they remain tight.
o
Periodically check the safety relief valve
–
ensure air is released when the manual override is pulled.
Note:
The compressor does not use oil lubrication
–
there is no requirement to check / fill oil.
Troubleshooting Guide
This is a basic guide for field troubleshooting only. If the compressor does not operate after taking these
steps, refer to a TJM distributor.
Problem
Possible Cause
Resolution
Compressor does not run
Thermal cut-off
switch active
Switch off power, wait 45 minutes for
compressor to cool, restart.
Wiring Fault
Check that wiring has been connected
according to diagram. Check power
switch illuminates green with dash lights
and red when switched on.
Fuse blown
Replace 40 A Maxi blade fuse.
Relay blown
Test with another relay and replace if
required
Faulty pressure
switch
Check for voltage at relay terminal 86.
Replace switch if required.
Compressor switches on and off
frequently
Air leakage
Check all air lines and fittings for leaks.
Compressor does not switch off at
120 PSI (observe relief valve opens
while running)
Faulty pressure
switch
Replace pressure switch.
Compressor air flow lower than normal Blocked air filter
Inspect air filter and replace if dirty.
Unusual noise or vibration
Worn isolators
Replace isolators.
Loose mounts
Tighten all mount bolts.