CAUTIONS

This DSF2 is designed to work in an ambient air condition between -10oF to +130oF (-23oC to +54oC). Operation of the DSF2
outside of this temperature range can destroy DSF2 and will void the warranty.

This DSF2 is factory wired for a grounded 120 VAC power outlet. Use one Tjernlund Products, Inc., p/n DSF2TR  transformer per
DSF2 for single phase power supplies of 208, 220, 230, 240, 277 and 480 VAC applications.

Make sure to install the DSF2 away from furnaces and other high heat sources. Excessive heat may destroy the DSF2.

This DSF2 was designed to be used in sheltered applications only. Do not use in applications where moisture from rain or snow
may enter the DSF2. Damage to the DSF2 from moisture will void warranty.

This DSF2 has rotating components that are unguarded. Use care to insure nothing comes in contact with the moving 

parts. 

Keep

the power cord and other ceiling level wiring clear of the DSF2.

To properly mount and support the DSF2, use the mounting hardware and secondary safety cable as directed. Make sure the
safety cable is connected to the roof truss or other load rated structural component. Follow the installation details found in these
instructions.

MOUNTING OPTIONS

The DSF2 can be mounted to the 
bottom bars of a Bar Truss.

The DSF2 can be mounted to the bottom
angles of a Angle Iron Truss.

The DSF2 can be mounted to a rod or 
pipe mounted between two Trusses.

The DSF2 can be mounted from a wall. (Installer 
must provide proper bolts and wall anchors).

Summary of Contents for DSF2B

Page 1: ...RUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION ADJUST MENT SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE ELECTRI CAL SHOCK PERSONAL INJURY OR PROPERTY DAMAGE WARNING DO NOT DESTROY PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE MODELS DSF2W WHITE DSF2B BLACK REV 0417 TJERNLUND PRODUCT...

Page 2: ...et in table based on ceiling height Round to closest whole number for suggested quantity of fans Example 7500 square foot area with 16 ceilings 7500 1200 16 foot ceiling height in table 6 25 This application would need 6 DSF2 fans DSF2 SPECIFICATIONS Volts 115 VAC Hz 50 60 Amps 0 24 Watts 30 CFM 540 Thermal Limit 196 F 91 C Unit dimensions with mounting bracket Height 25 Width 12 1 8 Weight 21 lbs...

Page 3: ... rain or snow may enter the DSF2 Damage to the DSF2 from moisture will void warranty This DSF2 has rotating components that are unguarded Use care to insure nothing comes in contact with the moving parts Keep the power cord and other ceiling level wiring clear of the DSF2 To properly mount and support the DSF2 use the mounting hardware and secondary safety cable as directed Make sure the safety ca...

Page 4: ... Mounting Hardware Shown Assembled Lock Washer Bracket Nut Lock Washer Bracket Nut Loop safety cable around solid anchor point Feed cable with clamp through DSF2 holes Feed cable end through clamp as instructed Feed cable back through clamp with minimum 6 tail TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products Inc warrants to the original purchaser of this product that the product will be free...

Reviews: