720D Driver Connections

M

LINEARdrive 720D

12-28V / 24W Direct voltage controlled LED driver

TC

Group 1

Group 1 GND

Group 2

Group 2 GND

Group 3

Group 3 GND

Group 4

Group 4 GND

Ext in +

Ext in

 -

DMX in +
DMX in -

LedSync out +
LedSync out -
LedSync shield

DA -

DA +

DA -

DA +

Ext in +

Ext in -

DA +

DA -

DA +

DA -

DMX in +

DMX -

DMX in shield

LedSync out +

LedSync -

LedSync shield

Channel 1, Red
Power
Channel 2, Green
Power
Channel 3, Blue
Power
Channel 4, White
Power

M

LINEARdrive 720D

12-28V / 24W Direct voltage controlled LED driver

TC

Group 1

Group 1 GND

Group 2

Group 2 GND

Group 3

Group 3 GND

Group 4

Group 4 GND

Ext in +

Ext in

 -

DMX in +
DMX in -

LedSync out +
LedSync out -
LedSync shield

DA -

DA +

DA -

DA +

Ext in +

Ext in -

DA +

DA -

DA +

DA -

DMX in +

DMX -

DMX in shield

LedSync out +

LedSync -

LedSync shield

Channel 1, Red
Power
Channel 2, Green
Power
Channel 3, Blue
Power
Channel 4, White
Power

12V-48V DC IN

To connect the driver to a 12-48V DC power supply, connect 

the power supply positive voltage supply wire to the VDC+ 

connector and the negative voltage supply wire to the VDC-

connector. The driver and LEDs can use the same power 

supply.

EXT in

Connect an external control device to the driver’s Ext in+ 

and Ext in- connectors. Configure the driver for use with as 

external control device over the 3-button user interface.

DA+ / DA-

Use these connectors to connect the driver to a DALI network. 

Always combine a DA+ and a DA- connector for either data 

input or data output.

DMX in/LEDSync out

Use these connectors when the driver is used in a DMX 

network.

For DMX in, connect the network cable’s DMX+, DMX- and 

DMX shielding wire (the orange/white, orange and brown wire 

in a CAT5 cable) to the DMX in+, DMXin-, and DMX in shield 

connector respectively.

For LEDSync out, connect the network cable’s data+, data- 

and shielding wire to the LEDSync out+, LEDSync out- and 

LEDSync shield connector respectively.

LED Lighting

Indicates the location of the connectors for your LED lighting. 

Red represents channel 1, Green represents channel 2, Blue 

represents channel 3 and White represents channel 4. The 

default group color allocation can be changed over the 3 

button user interface.

Summary of Contents for ADNM-DTV

Page 1: ...will require a de rating in output current This power supply will operate efficiently between 40 C to 80 C with adequate ventilation The enclosure is NEMA 3R rated for outdoor wet applications Outdoo...

Page 2: ...ircuit Installer is responsible for selecting the right size wire for run length and total wattage for each circuit Do not exceed rated watts per circuit Power Supply Connect transformer input to 120...

Page 3: ...wire to the VDC connector and the negative voltage supply wire to the VDC connector The driver and LEDs can use the same power supply EXT in Connect an external control device to the driver s Ext in a...

Page 4: ...nals will be reflected when they reach the end of the cable These reflections can cause eratic behavior lake random flashing lights wrong brightness levels etc To get the most reliable operation with...

Page 5: ...splay off M External input EXT INP LOG LIN Dimming curve M DIM CURV OFF VID COLR WHIT GLOW M M M M 1 512 Network resolution DMX address 8 BT 16 BT ADDR DMX RES NETW Interpolation AUTO MANU display off...

Page 6: ...roup 1 GND Group 2 Group 2 GND Group 3 Group 3 GND Group 4 Group 4 GND RGB LED strip R G B 32A PSU 6A 6A 6A 6A 6A 6A 6A 6A White LED strip 6A 24A 24A 18A TC Group 1 Group 1 GND Group 2 Group 2 GND Gro...

Page 7: ...Power Supply Negative Wire To Luminaire Positive Wire 16ga Wire DMX In DMX In DMX In Shield To TivoCue 22ga Wire G R B W Lead Wire W B G R 12V DC RGB Luminaire ADNM 60 1 5 12 DTV Outdoor Nema 3 Rated...

Page 8: ...6ga Wire Incoming Power To Luminaire 4 Circuits M LINEARdrive 720D 12 28V 24W Direct voltage controlled LED driver TC Group 1 Group 1 GND Group 2 Group 2 GND Group 3 Group 3 GND Group 4 Group 4 GND Ex...

Reviews: