SETUP1
Configurable Item
Setting
Backlight Brightness
One
Boost Overrun
Kitchen
15
mins
Wet Room
15
mins
Boost Delay Timer
Kitchen
0
mins
Wet Room
0
mins
Boost Inhibit On/Off
Off
Boost Inhibit Times
Start
23
:
00
End
05
:
00
%RH Boost Set point
70
%
SETUP2
Configurable Item
Default
Filter Change Interval
12
months
Boost Overrun Timer
Kitchen
15
mins
Wet Room
15
mins
Boost Delay Timer
0
mins
Speed 4 SUMMERboost® Supply
100
%
Extract
100
%
Boost Alert On/Off
On
Boost Alert Timer
2
hours
Summer Mode Enable/
Disable
Disable
Summer Mode
Extract
22
°C
Supply
18
°C
Supply Fan
Speed
0
%
Summer By Pass Enable/
Disable
Enable
Summer By Pass
Extract
25
°
C
Supply
18
°C
SUMMERboost®
Enable
Duct Heater Enable/
Disable
Disable
Duct Heater
Frost
Hyst
1
°C
Duct Heater threshold
4
°C
Configurable Item
Default
Room Sensor 1
Set point Low
0060
Set point High
0070
Room Sensor 2
Set point Low
0800
Set point High
1400
Internal Humidity Boost
Off
%RH Boost Overrun
timer
15
%
%RH Boost Hysterisis
1
%
SETUP3
Configurable Item
Default
Continuous SPEED2
Supply
40
%
Extract
40
%
Boost SPEED3
Supply
70
%
Extract
70
%
Setback SPEED1
Supply
18
%
Extract
18
%
SPEED4 SUMMERboost®
Supply
100
%
Extract
100
%
Frost set point
2
°C
Frost Protection Mode
Off
Room Sensor 1 Enable/
Disable
Disable
Room Sensor Type
%RH
Sensor Min Point 0V
0020
Sensor Max Point 10V
0090
Room Sensor 2 Enable/
Disable
Disable
Room Sensor Type
CO₂
Sensor Min Point 0V
0450
Sensor Max Ponit 10V
1850
Switch Input 1
Kitchen
Switch Input 2
Wet Room
Switch Input 3
SUMMERboost®
Live Switch 1 (LS1)
Kitchen
Live Switch 2 (LS2)
Wet Room
Installed Configuration.
The Tables below MUST be completed by the installer with all configured setting that deviate from the defaults.
Default values shown
greyed out.
22
Summary of Contents for aurastat VT
Page 1: ...ventilation systems aurastat VT TP534 HRV Controller Product Manual EN ...
Page 25: ...verrun Setup Boost Delay Timer Boost Inhibit On Off Setu Inhi 25 ...
Page 26: ...Setup Boost Inhibit Times Done Setup Internal Humidity Boost Partial SETUP1 2 of 2 26 ...
Page 29: ...verrun Setup Boost Delay Timer Setup Speed 4 SUMMERBoost Boost Alert On Off Setu Boo Time 29 ...
Page 31: ...Summer By Pass Enable Disable Setup Summer By Pass 31 ...
Page 34: ...SETUP2 4 of 4 Setup Internal Humidity Boost Full Done 34 ...
Page 43: ...ted ys Done is available after Day 7 Setup is complete Done 43 ...