14
RL60-2 /
Manual
Titgemeyer / 10342EN1121 / 1
English
Setup of the X-dimension
To achieve a good grip of the jaws with
the mandrel and just enough opening to
allow a smooth and not scratching inserti-
on of the mandrel in the tool, the correct
setup of the x-dimension is relevant. The
first setting is performed by the manufac
-
turer to x=84mm (basic setting).
If it is necessary, adjust the x-dimen-
sion by counter nut and spacer by using
wrenches no. 15 and 12. Maximum
allowed X-dimension is 86 mm with
default nosepiece and pulling head.
Minimum X-dimension is limited by the
thread on the piston. With higher size of
X-dimension it is possible to reach wider
jaw opening in case the rivet mandrel
gets stuck in the jaws. On the other
hand with lower X-dimension the jaws
may grip the mandrel faster.
This is advantageous in situation where
the mandrel is short and the jaws grip
it in the back. It is always necessary
to check if the pulling head does not
collide with the nosepiece to prevent
any damage.
Oil refilling
—
Oil needs to be refilled when the wor
-
king stroke is reduced during working
process
—
During oil refilling, prevent dirt from
entering the hydraulic system
— Disconnect the tool from the compres-
sed air
— Remove the nosecap (see chapter
jaws cleaning and replacement)
— Use allen key no. 4 to unscrew the
screw in the top of the tool
— Fill up the syringe with the recommen-
ded hydraulic oil (chapter 19. Technical
parameters), attach it to the brass adap-
ter and screw the adapter on the outlet
— Press the hydraulic oil into the tool
and pump the syringe piston several
times. As you are pumping, you can
see that the hydraulic piston is mo-
ving forward and backwards.
— Unscrew the adapter, mount the screw
and USIT ring, mount the nosecap (see
chapter jaws cleaning and replacement)
— Clean the tool from any spilled oil
— Activation of the tool without rivets -
Spacer
Counter nut
X-dimension, basic setup
Disassembly of the oil refill screw