background image

 

2

 

SCHEMATIC 

 

 

 

 

 

 

FIGURE 3 

 

WIRING INSTRUCTION 

 
(1)   Switch off the power source or wall switch. 

 

(2)    Strip  approximately  6-8mm  insulating  part  of  the 

wires from the power cord.   

 

(3)    Connect the BROWN wire (Live wire) of power 

cord to the terminal block "L" mark. 

 

        Connect the BLUE wire (Neutral wire) of power 

cord to the terminal block “N” mark.   

 

        Connect the RED wire of lamp wire to the 

terminal block "LS" mark. (FIGURE 4) 

 

 

 

 

 

 

 

  FIGURE 4 

 

 

 

(4)    Fit the main body to the wall box of the ceiling 

and secure it with two fixing screws provided. 

(FIGURE 5) 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 5 

The product is also designed to fit a standard UK spec 

pattress box. 

 

SETTING THE LIGHTING SYSTEM

 

(1)  TEST MODE 

 

Turn the Lux control and the Time control 

counter-clockwise to the edge-the TEST position. 

(FIGURE 6)

 

 

 

 

 

 

 

FIGURE 6 

 

Turn the power supply or wall switch on, the light 

will  turn  on  immediately  and  wait  for  about  1 

minute  to  warm  up  the  unit.    After  warming-up 

time  is  expired  and  the  light  goes  off,  you  may 

make a walk test and the light will turn on.    This 

confirms  that  the  wiring  was  done  properly  and 

that the light is working. 

 

Walk  through  the  coverage  area.    The  light  will 

turn on for about 5 seconds when motion is 

      detected and turn off shortly after the area is fully 

vacated.     

 

(2)  SETTINGS 

 

 

TIME ADJUSTMENT 

The  TIME  adjustment  controls  how  long  the  light  will 

stay on after motion has been detected. 

 

Adjust  the  TIME  Control  Knob  clockwise  to  increase 

the  turn-off  time  (40  minutes  maximum)  or 

counter-clockwise  to  decrease  the  turn-off  time  (5 

seconds minimum). (FIGURE 7) 

 

 

 

 

 

 

 

 

                                       

  FIGURE 7 

 

LUX ADJUSTMENT 

The LUX adjustment determines at what light level the 

light will start operating when you set the sensor to the 

AUTO mode. 

L

N

AC POWER

Brown
Blue

Red