Engine oil is a major factor affecting engine performance and service life. Non detergent and 2-stroke
engine oils will damage the engine and are not recommended.

Check the oil level BEFORE EACH USE with the
generator on a level surface and the engine stopped.
Use 4-stroke motor oil that meets or exceeds the
requirements for API service classification SJ.
Always check the oil container for the SJ classification.

SAE 10W-30 is recommended for general, all-temperature use. Other
viscosities shown in the chart may be used when the average temperature in your area is within the
indicated range.
1. Remove the oil filler cap and wipe the dipstick clean.
2. Check the oil level by inserting the dipstick into the filler neck without screwing it in.
3. If the level is low, fill to the top of the oil filler neck with the recommended oil.

Engine Oil Change

Drain the oil while the engine is warm to assure rapid and complete draining.

1. Remove the drain plug and sealing washer, remove the oil filler cap, and drain the oil.
2. Reinstall the drain plug and sealing washer. Tighten the plug securely.
3. Refill with the recommended oil and check the oil level to ensure it is full.

OIL CAPACITY: 32 oz.

Wash your hands with soap and water after handling used oil.

Please dispose of used motor oil in a manner that is compatible with the environment. We suggest
you take it in a sealed container to your local service station or recycling center for reclaimation.
Do not throw it in the trash, pour it on the ground, or down a drain.

7

Summary of Contents for TG 8500M

Page 1: ...rating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not Operate Equipm...

Page 2: ...TION THE TITAN INDUSTRIAL INC MODEL TG 8500M is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for com patible electrical tools motors applian...

Page 3: ...e dam aged electrical cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive va...

Page 4: ...p generator with electri cal devices plugged in Allow the generator engine to run at a No Load condition for several minutes to stabilize internal engine temperature before stopping Turn the On Off Sw...

Page 5: ...vel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the...

Page 6: ...6 Control Panel Circuit Breakers Stop Switch 3 Prong L5 30 120v 120v Receptacle 4 Prong Receptacle L14 30 Ground Lug...

Page 7: ...Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low fill to the top of the oil filler neck with the recommended oil Engine Oil Change Drain...

Page 8: ...evice Running Watts Device Running Watts Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU...

Page 9: ...Storage 9...

Page 10: ...10...

Page 11: ...ual Start 11hp Titan Gasoline Engine Steel Sleeve Cylinder 5 Gallon Fuel Tank Approx Run Time 10hrs 50 Load TITAN INDUSTRIAL P O Box 791 Travelers Rest S C 29690 800 845 4141 www titanindustrial net R...

Page 12: ...O Box 791 Travelers Rest SC 29690 Phone 864 834 7212 Fax 864 834 5127 Service Replacement Parts 800 845 4141 www titanindustrial net MODEL 8500M Industrial Generator MODEL TG 8500M Industrial Generato...

Reviews: