TITAN INDUSTRIAL shall not be responsible for any consequences resulting from improper use of
this equipment. The operator is required to read the entire contents of this manual before attempting
to operate the unit. If the operator does not completely understand the instructions and all of the
hazards of operating this unit after reading this manual, he/she must call the factory at 1-800-845-4141
to answer these questions to his/her complete satisfaction before proceeding.

READ AND COMPLETELY UNDERSTAND

entire contents of this Owner’s Manual and become familiar with

the unit before attempting to start using this equipment! It is your responsibility to know its applications,
limitations, and hazards! Call the factory at 1-800-845-4141 with any questions.

FOR OUTDOOR USE ONLY!

Never use this unit inside any enclosure including

the generator compartment of a recreation vehicle (RV) or inside any building. No
modifications will eliminate the danger of possible carbon monoxide poisoning, fire,
or explosion.

TWO (2) FEET OF CLEARANCE

on all sides is required even while using outdoors.

This unit is sold solely for the purpose of portable power. Other applications could void warranty.
User accepts responsibility for injuries and/or damage resulting from other applications.

IMPORTANT !

READ FIRST

OWNER’S

MANUAL

MODEL TG 8500M

Industrial Generator

2

DESCRIPTION

THE TITAN INDUSTRIAL INC. MODEL TG 8500M

is a

gas engine driven, revolving field, alternating current (AC)
generator designed to supply electrical power for com-
patible electrical tools, motors, appliances, and lighting
(see wattage reference guide on page 8).

The Model TG 8500M operates at 120 volt and/or 240
volt, single phase, 60 Hz and will operate devices that
require up to 7200 watts continuous and 8400watts surge.

GROUNDING THE GENERATOR

It is required by The National Electrical Code to have
the frame and all external conductive parts of the gen-
erator connected to an earth ground. Proper ground-
ing also satisfies most local electrical codes.

Connect a No. 12 AWG standard copper wire to the
Grounding Lug Block (See Figure 1). The grounding
lug can be found on the control panel. Connect the
other end of the wire to an earth driven copper or brass
grounding rod (electrode).

CAUTION!

Do not connect ground to a preexisting

ground rod, water pipe, or building frame.

Consult with a licensed electrician in your area because
local codes vary. Properly grounding the generator
helps prevent electrical shock if a ground fault condi-
tion exists in the generator or in connected electrical
devices. This will also help to dissipate static electricity
resulting from ungrounded devices.

Figure #1 - Grounding Lug

B l o c k

CAUTION!

Do not tamper with en-

gine governed speed. The TITAN IN-
DUSTRIAL GENERATOR supplies
correct rated frequency and voltage
when running at the proper governed
speed. Incorrect frequency and/or
voltage could damage connected
electrical devices.

Summary of Contents for TG 8500M

Page 1: ...rating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not Operate Equipm...

Page 2: ...TION THE TITAN INDUSTRIAL INC MODEL TG 8500M is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for com patible electrical tools motors applian...

Page 3: ...e dam aged electrical cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive va...

Page 4: ...p generator with electri cal devices plugged in Allow the generator engine to run at a No Load condition for several minutes to stabilize internal engine temperature before stopping Turn the On Off Sw...

Page 5: ...vel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the...

Page 6: ...6 Control Panel Circuit Breakers Stop Switch 3 Prong L5 30 120v 120v Receptacle 4 Prong Receptacle L14 30 Ground Lug...

Page 7: ...Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low fill to the top of the oil filler neck with the recommended oil Engine Oil Change Drain...

Page 8: ...evice Running Watts Device Running Watts Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU...

Page 9: ...Storage 9...

Page 10: ...10...

Page 11: ...ual Start 11hp Titan Gasoline Engine Steel Sleeve Cylinder 5 Gallon Fuel Tank Approx Run Time 10hrs 50 Load TITAN INDUSTRIAL P O Box 791 Travelers Rest S C 29690 800 845 4141 www titanindustrial net R...

Page 12: ...O Box 791 Travelers Rest SC 29690 Phone 864 834 7212 Fax 864 834 5127 Service Replacement Parts 800 845 4141 www titanindustrial net MODEL 8500M Industrial Generator MODEL TG 8500M Industrial Generato...

Reviews: