SAFETY

This generator was designed for specific applications. DO NOT attempt to modify the unit in any way or use it
for any application that it was not designed to do. Ask the dealer or contact the factory if you have any ques-
tions concerning the generator’s application.

Warnings and cautions in this manual and on decals and tags on the unit are not all inclusive. It would be
impossible to anticipate every circumstance that might involve a hazard. Handling, operating, or servicing
this unit by any procedure not recommended by the manufacturer may render this equipment unsafe and
may pose a threat to you or to others.

CAUTION! The engine exhaust contains chemicals
known to the State of California to cause cancer,
birth defects, or other reproductive harm.

The generator produces a very powerful volt-
age that can cause extremely dangerous elec-
trical shock. Avoid contact with bare wires, ter-
minals, etc. never permit an unqualified person
to operate or service the generator.

Never handle any kind of electrical cord or de-
vice while standing in water, while barefoot or
with wet hands or when feet are wet. Danger-
ous electrical shock could result.

The National Electric Code requires that the
frame and external conductive parts be prop-
erly connected to an approved earth ground.
Local electrical codes may vary. Check with an
electrician for local grounding requirements.

Use a ground fault circuit interrupter in any damp
or highly conductive area such as metal deck-
ing or steel work.

Do not use worn, bare, frayed or otherwise dam-
aged electrical cords or wiring with the genera-
tor. A defective cord may result in electrical
shock or may cause damage to equipment.

Do not expose unit to excessive moisture, dirt
or corrosive vapors. Unit must be operated on
a level surface.

Do not overfill the fuel tank. Always allow room
for fuel expansion. Fuel could overflow and
cause fire or explosion if tank is overfilled. Al-
low for a 20 minute cool down before refueling.
Never refuel tank while engine is running.

Only operate this unit outside with adequate venti-
lation. This generator’s exhaust produces carbon
monoxide gas that can cause unconsciousness or
even death.

Never store a generator with fuel in the tank where
fuel vapors could be ignited by a flame, spark, or
pilot light from an appliance such as a furnace, water
heater, or clothes dryer.

Always allow a minimum of 2 feet of clearance on
all sides for ventilation while unit is operating. Al-
low 2 feet of clearance from all combustibles.

Generator must always be stopped or started with
all loads unconnected. Start the engine and let it
stabilize before connecting any loads. Disconnect
all loads before shutting down the generator.

Never insert any object through the cooling slots of
the engine. You could damage the unit or cause
injury.

NEVER OPERATE THE GENERATOR:

In rain
In an enclosed compartment
If connected devices overheat
If electrical output is lost
If engine or generator sparks
If flame or smoke is observed
If unit vibrates excessively

CAUTION! If it is your first time starting the gen-
erator, allow it to run for 30 minutes before con-
necting electrical loads. This is for wet seating
purposes

Caution: Customer takes full responsibility for
use of this unit as a home generation system

.

3

Summary of Contents for TG 8500M

Page 1: ...rating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not Operate Equipm...

Page 2: ...TION THE TITAN INDUSTRIAL INC MODEL TG 8500M is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for com patible electrical tools motors applian...

Page 3: ...e dam aged electrical cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive va...

Page 4: ...p generator with electri cal devices plugged in Allow the generator engine to run at a No Load condition for several minutes to stabilize internal engine temperature before stopping Turn the On Off Sw...

Page 5: ...vel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the...

Page 6: ...6 Control Panel Circuit Breakers Stop Switch 3 Prong L5 30 120v 120v Receptacle 4 Prong Receptacle L14 30 Ground Lug...

Page 7: ...Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low fill to the top of the oil filler neck with the recommended oil Engine Oil Change Drain...

Page 8: ...evice Running Watts Device Running Watts Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU...

Page 9: ...Storage 9...

Page 10: ...10...

Page 11: ...ual Start 11hp Titan Gasoline Engine Steel Sleeve Cylinder 5 Gallon Fuel Tank Approx Run Time 10hrs 50 Load TITAN INDUSTRIAL P O Box 791 Travelers Rest S C 29690 800 845 4141 www titanindustrial net R...