TA 250 / TA 450
(0001)
62
/
112
Fault
Cause
Remedy
Strap tension isn’t enough.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Li-Po storage battery
insufficiently charged.
Check charge of Li-Po storage
battery and recharge it.
Tension motor
(506)
, gear unit
(77)
or circuit board
(19)
defective or worn.
Check tension motor
(506)
, gear
unit
(77)
and circuit board
(19)
for
damage (visual inspection),
if
existing contact TITAN service
dept.
Plastic strap tears when being
tensioned.
Strap tension setting too high.
Correct strap tension value set on
the operator panel downward.
Edges of packing item too
sharp.
If sharp packing item edges exist,
use an edge saver.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
Feed wheel slips trough.
Feed wheel
(85)
and/or gripper
plates
(5 / 8)
were polluted.
Gearing is worn or defective.
Clean feed wheel
(85)
and/or
gripper plates
(5 / 8)
. Check
gearing, replace when damage
becomes visible.
Strap tension setting too high.
Correct strap tension value set on
the operator panel if necessary.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
Seizing signs on plastic strap.
Ambient temperature too high.
Reduce the ambient temperature.
Gap between feed wheel
(85)
and gripper plate
(5)
is too
small.
Increase the gap between feed
wheel
(85)
and gripper plate
(5)
, ask
your TITAN
– Adviser for advice.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
The plastic strap tensioned is
bent on its side, it is not proper
within the strap guidance
’s; the
seal is not in the centre.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Strap mismatch not set
correctly.
Set strap mismatch correctly, see
item 8.4.
Strap dimension and strap
guidance’s does not fit together.
Check strap dimension and strap
guidance
’s, they must fit together, if
required replace the strap
guidance’s or use other strap.
During the tensioning operation
the tool moves forward.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Gripper plates
(5 / 8)
were
polluted, gearing is worn or
defective.
Clean gripper plates
(5 / 8)
, check
gearing, replace when damage
becomes visible.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
After the tensioning operation
the tool moves backward and
the plastic strap loosens.
Free wheel
(74)
or drawn cup
roller
(81)
and/or plastic strap
holding unit were defective.
Contact TITAN
– Service.
H TA 250 / 450 EU 38/15
Summary of Contents for TA 250
Page 34: ...TA 250 TA 450 0001 34 112 12 Konformitätserklärung H TA 250 450 EU 38 15 ...
Page 64: ...TA 250 TA 450 0001 64 112 12 Declaration of conformity of the machine H TA 250 450 EU 38 15 ...
Page 95: ...TA 250 TA 450 0001 95 112 12 Déclaration CE de conformité des machines H TA 250 450 EU 38 15 ...
Page 98: ...TA 250 TA 450 0001 98 112 13 2 TA 450 B TA 250 TA 450 EU 38 15 13 16mm 1 2 5 8 ...
Page 100: ...TA 250 TA 450 0001 100 112 B TA 250 TA 450 EU 38 15 ...
Page 106: ...TA 250 TA 450 0001 106 112 B TA 250 TA 450 EU 38 15 ...