13
description of unit / operation
PowrBeast
operATINg TemperATure
This equipment will operate correctly in its intended ambient,
at a minimum b50ºF (10°C) and 104ºF (+40°C).
relATIVe humIDITy
The equipment will operate correctly within an environment
at 50% RH, 104ºF (+40°C). Higher RH may be allowed at lower
temperatures.
Measures shall be taken by the Purchaser to avoid the harmful
effects of occasional condensation.
AlTITuDe
This equipment will operate correctly up to 2100 m above
mean sea level.
TrANSporTATIoN AND STorAge
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -13ºF (-25°C) to
131ºF (+55°C) and for short periods up to 150ºF (+70°C).
It has been packaged to prevent damage from the effects of
normal humidity, vibration and shock.
3.6
TrANSporTATIoN
TrANSporTATIoN IN VehIcle
Secure the unit with a suitable fastening.
puShINg or pullINg The uNIT
Pull out the handle (Fig. 5, Item 1) until it will come no further.
Insert the handle – push the buttons (2) on the cart, and then
push in the handle.
2
1
4
operATIoN
This equipment produces a fluid stream at
extremely high pressure. Read and understand
the warnings in the Safety Precautions section
at the front of this manual before operating this
equipment.
4.1
SeTup
1. Make sure the bleed hose (Fig. 6, item 1) is threaded into
the bleed valve (2). It has factory installed PTFE tape on
the fitting and should be tightened wrench tight.
2. Attach a minimum of 50’ (15 m) of nylon airless spray hose
(3) to the sprayer. Do not use PTFE tape or thread sealant
on the spray hose connection.
2
1
3
3. Attach an airless spray gun to the spray hose. Do not
attach the tip to the spray gun yet. Remove the tip if it is
already attached.
i
For multiple gun operation, connect a multiple
gun manifold to the single gun outlet. Connect
a hose and gun to each outlet. Make sure
the second gun outlet remains plugged. See
“Technical Data”, Section 3.5 to determine
number of guns and maximum spray tip sizes.