background image

 

Electro
TS600 

5.1 

o-Pneumatic

Series 

Power C

 

 

Always
to  rem
electric

 

Check 

 

Flame pro

 

Be  sur
explos
proof, e

 

Do not

 

Covers

 

Cable Glan
 

  Be sur

potenti

when u

   Insert 

  Insert w

c Positioner

Connec

s check that 

ain  within  e

cal switches,

polarity of +

oof type p

re  that  exter

ion-protectio

explosion pro

t remove term
s for the term

nd Connecti

e to use the 

ially-explosiv

using the flam

the terminal 

washer and r

<F

ction 

 

the electrica

lectrical  ratin

 sensors or t

and – exact

ower conn

rior  lead-in  w

on  of  manufa

oof construct

minal cover in

minal and bod

ion 

flameproof-a

ve area. Use 

meproof-app

connection 

rubber packi

lame proof / 

24 

 WAR

al load is with

ngs  may  res

transmitter e

tly and conne

nection

 

 WAR

wiring  to  the 

actory  electr

ction. 

n a hazardou

dy should be

approved wir

the cables s

proved cable 

into terminal

ing, and faste

ATEX & IEC

RNING 

hin the range

sult  in  damag

electronics.

ect wires. 

RNING 

terminal  bo

ric  equipmen

us location w

e in place wh

res and cable

suitable for th

glands. 

l box and loc

en the cable 

CEx approve

 stated on th

ge  to  or  pre

x  is  based  o

nt  when  bei

while the pow

ile operating

e glands in th

he diameter o

ck completely

gland comp

d cable glan

t

he nameplate

emature  failu

on  the  guide

ng  used  as

wer is on. 
g. 

he gas area 

of the NBR p

y.  

pletely. 

nd>

            

issin

e. Failure 

re  of  the 

elines  for 

a  flame 

or in the 

packing 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TS600 Series

Page 1: ...Ele ectro P Inst Pneum TS truct matic P S60 tion M Ver PM Positio 00 Se Man M TS600EN oner eries ual 12 2020...

Page 2: ...n 7 2 2 Features 7 2 3 Options 7 2 4 Applications 7 2 5 Label 8 2 6 Product Code 9 2 7 Specification 10 2 7 1 Positioner 10 2 7 2 Position transmitter Option 10 2 7 3 Limit Switch Option 11 2 8 Operat...

Page 3: ...Flame proof type power connection 24 5 2 Intrinsically safe type power connection 26 5 3 With Position transmitter 27 5 4 With Limit switch 28 5 5 With Position transmitter and Limit switch 28 6 Adju...

Page 4: ...erator to do so To avoid possible injury to personnel or damage to valve parts WARNING CAUTION and NOTICE should be strictly followed Before installing or commissioning be sure to read and thoroughly...

Page 5: ...in product failure or injuries NOTICE Failure to observe this warning may result in product failure or performance degradation Safety notes CAUTION Only trained and authorized person should operate ma...

Page 6: ...ns area TS600 series has 2 conduit entries Flameproof cable must be used for cable entry and for unused cable entry flameproof blind cable plug should be used TS600 series is certified under flame pro...

Page 7: ...d span adjustment IP 66 enclosure Easy maintenance due to built in module type By pass valve A M switch installed Air connection part is designed for detachability and it can be changed PT NPT tapping...

Page 8: ...Indicates Indicates Indicates Indicates Indicates This tem explosio Indicates Indicates Indicates 8 ption s model num s serial num s allowable o s certified ex s explosion p mperature ran on proof are...

Page 9: ...lever type 10 40mm 1 40 70mm 2 70 100mm 3 100 150mm 4 1 Rotary lever type M6 x 34L Fork lever type NAMUR Type 5 Operating Temp 20 70 Standard S 20 120 H 40 70 L Options None 0 With Position transmitte...

Page 10: ...otection IP66 Ambient Temp Operating Temp 20 70 Standard 40 70 Low Temp 20 120 High Temp Explosion proof Temp 40 60 T5 T100 40 40 T6 T85 Linearity 1 0 F S 2 0 F S 1 0 F S 2 0 F S Sensitivity 0 2 F S 0...

Page 11: ...tion Item type Specification Switch type 2 x SPDT Degree of protection IEC IP40 Rating AC 16A 1 2HP 125 250VAC Rating DC 0 6A 125VDC 0 3A 250VDC Durability Min 100 000 30 operation min Temperature rat...

Page 12: ...u re internal pr d Control valv 12 ward The mo k lever and F position betw t current Ga t Valve to the S600L Opera ns based on 00R rotary ty cture ressure of N ve consist of ovement of d lapper increa...

Page 13: ...Electro TS600 2 9 2 o Pneumatic Series Parts and 9 1 Stand c Positioner d Assembl dard type r y 13 tissin...

Page 14: ...14 Electro Pneumatic Positioner TS600 Series tissin 2 9 2 With Position transmitter type...

Page 15: ...ro Pneumatic Positioner TS600 Series tissin 2 10 Dimension Drawings 2 10 1 TS600L Dimensions TS600L Intrinsically safe type Non Explosion proof type Dimension TS600L Flame proof type ATEX IECEx type D...

Page 16: ...16 Electro Pneumatic Positioner TS600 Series tissin TS600L with Position transmitter type Dimension...

Page 17: ...he space between Flapper and Nozzle opens the Nozzle back pressure decreases As a result Exhaust valve of Pilot valve moves to right At the same time Supply valve A of OUT1 moves to right and opens Su...

Page 18: ...18 Electro Pneumatic Positioner TS600 Series tissin TS600R with Position transmitter type Dimension TS600R with Limit switch type with Position transmitter and Limit switch type Dimension...

Page 19: ...e made in or ortant points w lever is para nnection with ve stroke and 19 WAR e ensure to re ntenance on t se compress CAU rder to adap when a brac llel to the gro h the pin of t d numbers w RNING ead...

Page 20: ...er o manual pos stopper wh er touches th L Feedback 20 acket made positioner for acket Installat CAU operate the v sition On bo ich is located he stopper t lever should in previous s r size of the b t...

Page 21: ...or Type fork lever to indle so that pe tioner feedba r n cket include both fork lev TS600R actuator as t the concent ack shaft and 21 ed with the ver and NAM R Bracket Ins s shown belo trically layere...

Page 22: ...s s n RA DA Th Direct r n esigned to inc e shipped RA will be open DA Direct A tion Single actuat on setting hown below e product is Action 22 NO crease the in RA Reverse A Action must tor g the pipin...

Page 23: ...acti is used for D ckwise RA w to the side o DA Type r tion type actuato ion setting DA Direct Ac will face up t of the cam T 23 or g ction the in to the side of The product TS60 put signal wi f the c...

Page 24: ...area Use meproof app connection rubber packi lame proof 24 WAR al load is with ngs may res transmitter e tly and conne nection WAR wiring to the actory electr ction n a hazardou dy should be approved...

Page 25: ...te Make s Conne Close b c Positioner Wiring F terminal box e the poles an sure to faste ct Ground ca back the term r Flame proof t cover nd connect th n the connec able minal box cov 25 type ATEX hem...

Page 26: ...of er level than t rom damages e done prope box cover by to internal able box cover an ally safe type 26 r connectio WAR ntrinsically sa maged from e ages please ype circuit wit to prevent st f induct...

Page 27: ...ect polarit y and polarity precisely With Position transmitter type Terminal box Unlock the locking bolt of the terminal box and open the cover of the terminal box Connect the electric wire of the inp...

Page 28: ...28 Electro Pneumatic Positioner TS600 Series tissin 5 4 With Limit switch 5 5 With Position transmitter and Limit switch...

Page 29: ...to the actuator starting 0 point Then set the input current to 20mA DC and check the actuator stroke At this point depending on whether the span is too large or too small loosen the lock screw and the...

Page 30: ...ically and blinks Set input signal to 8mA to make the valve stroke on 25 and then press ZERO button just once it makes set to output 8mA and then lamp moves to number 12 automatically and blinks In th...

Page 31: ...2mm drill or wire and re fitted as original CAUTION The sensitivity adjustment screw is set optimally at the factory do not adjust at random 7 2 Install Orifice Failure When mounted on small size act...

Page 32: ...ndition e gear break ve stroke on xing screws f down slightly r gear so tha is complete 32 signal dead z eter gear brok colored poin tentiometer g ks away 0 and ope for Potentiom y which can at both w...

Page 33: ...es Corrective action Reference page Hunting period is too short and the width is too large pressure gauge moves at the same time of valve stem Actuator volume is too low Install the orifice on the bot...

Page 34: ...a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product Using...

Page 35: ...35 Electro Pneumatic Positioner TS600 Series tissin Note...

Page 36: ...Bucheon Tel 82 Fax 82 www t o Pneumatic Series n Co L 5 No 397 Seo Si Gyeonggi 32 624 4573 2 32 624 4574 issin co k c Positioner Ltd okcheon ro Oj i do Korea 14 4 kr r Solutions jeong gu 4449 36 for C...

Reviews: