33
Continued Table 12
1
2
3
Rotor gets stuck
intermittently during
rotation
Jamming in the mechanism
The sensor of position is set
wrong
The PCB.201.01.00.00 is
faulty
Check by hand if they work or
not
Check the mechanism parts
Setup the sensor of position or
change PCB
Check the wires
Replace PCB.201.01.00.00
Arm fails to lock in place/
drops by itself
Jammed arm locking
mechanism
Loose/ deformed arm lock
Damaged/worn arm locks
Repair jammed mechanism
Replace arm locks.
Turnstile unlocks but
motor does not work
The sensor of position is set
wrong
The PCB.201.01.00.00 is
faulty
Setup the sensor of position or
change PCB
Repair/ tighten connection
ReplacePCB.201.01.00.00
Replace motor
Rotor keeps moving, fails
to stop in middle position.
The sensor of position is set
wrong
Damaged wires between
sensor and controller
The sensor of position is
faulty
Setup the position sensor or
change the PCB
Change the wires
Check the contacts in the jacks
4.3 Post repair checkout
The turnstile performance to be checked after repair according to paragraph 2.3.2 of this
OM.
5 TRANSPORTATION AND STORAGE
5.1 Turnstile storage
It is forbidden to subject the turnstile to jerks and impacts during storage. Transportation
trolleys to be used for handling of the turnstile. In storage facilities there should not be
aggressive gases and vapours causing metal corrosion.
Air temperature during storage should not be below +50 С and above +400 С and relative
air humidity should not be more than 80% at the temperature 20° С.
5.2 Turnstile transportation
The ready
-
to
-
install turnstile to be transported according to the transportation regulations
related to the relevant mode of transport, such as:
– in railway or special containers;
– in closed vehicles;
– waterborne (in ship’s hold).
Transportation on open platforms is allowed. In this case the packed turnstile to be covered
with canvas. Air temperature during transportation should not be below
-
40°С and above +50°С.
After transportation or storage of the turnstile at negative temperatures or increased humidity the