CONNECTIONS
ELECTRICAL CONNECTION
Equipment type: Free standing (Class 1)
Insulation class: Class 1
The appliance is fitted with an approved 15
Amp flexible cord and plug which must be
connected to a correctly earthed socket
outlet.
CONNECTION OF THE SUPPLY
CABLE TO THE MAINS
Connect the supply cable to a plug suitable
for the load indicated on the rating plate of
the product. In case of a direct connection
to the mains (cable without plug), it is
necessary to insert a suitable omnipolar
switch before the appliance, with minimum
opening between contacts of 3 mm (the
grounding wire should not be interrupted by
the switch).
Before connecting to the mains, make
sure that:
1. All components used to make the
electrical connection are adequate to
withstand the maximum load required
(see rating plate).
2. The supply system is regularly
grounded, according to the regulations in
force.
3. The socket or the omnipolar switch
can easily be reached after the
installation of the oven.
WARNING // Never use reductions, shunts,
adaptors which can cause overheating or
burning.
ELECTRICAL FEATURES
NOTE // After carrying out the connection to
the mains, check that the supplying cable
does not come into contact with parts subject
to heating.
ATTENTION // If the supply cord is
damaged, it must be replaced by the
manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Oven Light
Upper Element
Bottom Element
Grill Element
Circular Element
Oven Fan Motor
Cooling Fan
15-25W
1500W
2000W
3250W
*1250Wx2 / 2200W
24W
15W
* only double turbo fan products.