6.5.3 Set RS-485 Parameters
The face recognition terminal can connect external access controller, secure door control unit or
card reader via the RS-485 terminal.
Steps
1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings
page.
2. On the Communication Settings page, tap RS-485 to enter the RS-485 tab.
Figure 6-9 Set RS-485 Parameters
3. Select an peripheral type according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4. Tap the back icon at the upper left corner and you should reboot the device if you change the
parameters.
6.5.4 Set Wiegand Parameters
You can set the Wiegand transmission direction.
Steps
1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings
page.
2. On the Communication Settings page, tap Wiegand to enter the Wiegand tab.