The  TimeTec  Barrier  Gate  Control  Relay  is  built  based  on  the  BLE  16  Lift  Relay 
Board. It is designed as an intermediate between a user’s mobile app and a residen-
tial barrier gate controller. The way it works is, a user uses his/her mobile app to send 
command to the TimeTec Barrier Gate Control Relay Board via Bluetooth connection. 
The board then translates the command into digital pulse and sends it to the barrier 
gate controller to open/stop/close the gate.

TECHNICAL SPECIFICATION

Specification

Model
Channels

Gates
Dimension (mm)
Weighing (kg)
Power input
Working Temperature °C
Humidity (%)
Card Storage
Communication
Effective Distance (m) 
LED indicator
Transaction Records
Event Capacity
Mobile OS
App & Cloud
Language (App & cloud)

BLE-2
2 FORM C Relay output, NO/NC selected via jumper 

Weigand 26-bit input  
Max 2 
100 (L) x 231 (W) x 62 (H)  
0.6  
9 ~ 24 VDC  
0-45 

20-80 
30,000 
Bluetooth Low Energy (BLE) 4.2, Weigand 26-bit input 

5 (For mobile app) 
Yes 
Unlimited, stored in cloud server  
Unlimited, stored in cloud server  

Android 4.0.2 and above, iOS 8.0 and above 
TimeTec VMS, TimeTec Access and i-Neighbour 

Arabic, Chinese Simplified, Chinese Traditional, English, Hindi, 

Indonesian, Malay, Nepali, Spanish, Thai, Turkish,Vietnamese. 

Other languages are available upon request.

Summary of Contents for BLE 2

Page 1: ...w w w i n e i g h b o u r c o m Installation Guide TimeTec BLE 2 Gate Control Relay Board ...

Page 2: ...tion Model Channels Gates Dimension mm Weighing kg Power input Working Temperature C Humidity Card Storage Communication Effective Distance m LED indicator Transaction Records Event Capacity Mobile OS App Cloud Language App cloud BLE 2 2 FORM C Relay output NO NC selected via jumper Weigand 26 bit input Max 2 100 L x 231 W x 62 H 0 6 9 24 VDC 0 45 20 80 30 000 Bluetooth Low Energy BLE 4 2 Weigand ...

Page 3: ...rs Static in orange Standby mode Blinking in orange Working mode device is sending open stop close Gate 1 command to auto gate panel Regulated input Open Stop Close FUNCTIONS Connect to power source ranging from 9 to 14 5V The relay output to barrier gate control panel Open port The relay output to barrier gate control panel Stop port The relay output to barrier gate control panel Close port ...

Page 4: ... It is important to shut down all your auto gates from any operations and disconnect the power supply before carrying out any installation or wiring job NO NC COM NO NC COM NO NC COM OPEN STOP CLOSE BARRIER GATE CONTROL PANEL DC12V3A REGULATED POWER ...

Page 5: ...ntrol Relay DO NOT SWITCH ON the power until all the wiring works are done Step 2 Connect Open Stop and Close relays NO and COM to the corresponding relay inputs into your auto gate control panel You can use NC and COM from TimeTec Auto Gate Control Relay if your auto gate control panel is using NC and COM as well Ignore the Stop relays if it is irrelevant Step 3 Turn on the power of the TimeTec B...

Page 6: ... 2018 Timetec Cloud Sdn Bhd All rights reserved 042018 w w w t i m e t e c c l o u d c o m ...

Reviews: