background image

 

Slim Relay

 G2RV

1

Slim Relay

G2RV

The World's First Industrial Slim Relay

• Large plug-in terminals for reliable connection.

• LED indicator and mechanical flag to check operation.

• Transparent housing enables checking relay condition.

• Slim outline to save space.

• Push-in terminals and accessories for easy wiring.

Model Number Structure

Model Number Legend

1. Auxiliary Type Designation

SL: Slim relay and socket combination

2. Wire Connection

7:  Screw terminals
5:  Push-in terminals

3. Relay LED

0:  Without LED

4. Relay Pushbutton

0:  Without pushbutton

5. Input Voltage

Note:

LED indicator available on socket.

Ordering Information

List of Models

Relay and Socket Combinations

1

2

3

4

5

G2RV-SL 

@ @ @ 

@

Classification

Enclosure rating

Input voltage

Type of connection

Contact form

SPDT

Plug-in terminals

General-purpose

Unsealed

AC/DC

Screw terminals

G2RV-SL700

Push-in terminals

G2RV-SL500

Input voltage

Screw terminals

Push-in terminals

12 VDC

G2RV-SL700-12 VDC

G2RV-SL500-12 VDC

24 VDC

G2RV-SL700-24 VDC

G2RV-SL500-24 VDC

24 VAC/DC

G2RV-SL700-24 VAC/DC

G2RV-SL500-24 VAC/DC

48 VAC/DC

G2RV-SL700-48 VAC/DC

G2RV-SL500-48 VAC/DC

110 VAC

G2RV-SL700-110 VAC

G2RV-SL500-110 VAC

230 VAC

G2RV-SL700-230 VAC

G2RV-SL500-230 VAC

Summary of Contents for G2RV - 1

Page 1: ... 4 Relay Pushbutton 0 Without pushbutton 5 Input Voltage Note LED indicator available on socket Ordering Information List of Models Relay and Socket Combinations 1 2 3 4 5 G2RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPDT Plug in terminals General purpose Unsealed AC DC Screw terminals G2RV SL700 Push in terminals G2RV SL500 Input voltage Screw terminals Pu...

Page 2: ... 500 VA 60 W Failure rate reference value 10mA at 5VDC P level Item 1 pole Contact resistance 100 mΩ max Operate set time 20 ms max Release time 40 ms max Max operating frequency Mechanical 18 000 operations hr Electrical 1 800 operations hr under rated load Insulation resistance 1 000 MΩ min at 500 VDC Dielectric strength 4 000 VAC 50 60 Hz for 1 min between coil and contacts 1 000 VAC 50 60 Hz f...

Page 3: ...ions G2RV SL Series SPDT 12 to 48 VDC 24 to 230 VAC 250 VAC 6 A Resistive Load 30 VDC 6 A Resistive Load 400 VAC 2 A Resistive Load 6 000 Contact form Coil ratings Contact ratings Operations 1 pole 12 24 VDC 24 48 VAC DC 110 230 VAC 250 VAC 6 A Resistive Load 30 VDC 6 A Resistive Load 400 VAC 2 A Resistive Load 50 000 50 000 6 000 ...

Page 4: ...ge VDC DC Breaking Current A Model number Operating time typical Release time typical G2RV SL7 5 DC12 5 7 ms 5 8 ms G2RV SL7 5 DC24 5 7 ms 6 9 ms G2RV SL7 5 AC DC24 5 7 ms 17 22 ms G2RV SL7 5 AC DC48 5 7 ms 22 30 ms G2RV SL7 5 AC110 12 15 ms 22 30 ms G2RV SL7 5 AC230 12 15 ms 22 30 ms Model number Description Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 series PNP type Ribbon cabl...

Page 5: ... Cable length as indictad by model number length in centimeters Split into 4 sections Length 30 cm 40 Pole B A D C Control line AWG26 0 14 mm2 tin plated copper Diameter cable 10 6 mm one end splits into 4 sections A B C D Operating voltage 60 VDC Continuous current per signal wire 0 5 A Max total current 4 bytes each 1 0 A Test voltage 0 5 KV 50 Hz 1 min Operating temperature range 20 C to 50 C M...

Page 6: ... VDC 21 VDC and 48 VDC List of Models Model number Cable length PLC type Configuration P2RV 200C SIM S7 300 2 0 m Siemens S7 300 4x1 Byte P2RV 250C SIM S7 300 2 5 m P2RV 300C SIM S7 300 3 0 m P2RV 500C SIM S7 300 5 0 m P2RV 200C SIM S7 400 2 0 m Siemens S7 400 4x1 Byte P2RV 250C SIM S7 400 2 5 m P2RV 300C SIM S7 400 3 0 m P2RV 500C SIM S7 400 5 0 m 1 2 3 4 5 6 G2RV Model number Replacement for G2R...

Page 7: ...kers for G2RV Sockets Model number Poles Color P2RVM 020 2 Red R Blue S Black B P2RVM 030 3 P2RVM 040 4 P2RVM 100 10 P2RVM 200 20 Max current EN60947 7 1 section 8 3 3 1991 32A Max Voltage 400 VAC Max Voltage when cutting Cross bar without using separation plate or end bracket 250 VAC 1 2 P2RVM Model number Box quantity Color R99 15 for G2RV 1 piece 1 sheet 120 labels White Model number Box quanti...

Page 8: ...lation between adjacent relays to achieve 400 V isolation 12 11 14 A1 A2 24 V DC Terminal Arrangement Internal Connections Top View 12 11 14 A1 A2 12 V DC Terminal Arrangement Internal Connections Top View 12 11 14 A1 A2 Other Coil Voltage Terminal Arrangement Internal Connections Top View Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit ...

Page 9: ...C Terminal Arrangement Internal Connections 12 11 14 A1 A2 Other Coil Voltage Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 Input circuit A2 A1 12 11 14 Terminal Arrangement Internal Connections Bottom View 30 5 max 3 5 0 5 2 4 1 8 5 2 max 5 04 5 04 3 22 33 max 16 2 Input circuit ...

Page 10: ...n used as an exclusive tool Applicable Wires Applicable Wire Sizes G2RV SL700 Series Box clamp technology G2RV SL500 Series Push in technology Flat blade Parallel tip Flat blade Flared tip 2 5 dia 3 0 mm max Cannot be used Wire type Applicable wire size Stripping length Stranded without ferrules 0 5 2 5 mm2 7 mm Stranded with ferrules and plastic collar 0 5 2 5 mm2 7 mm Stranded with ferrules with...

Page 11: ...d conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be removed after fully insertion of the wire Removing Insert the specified screwdriver into the release hole Removing wire Removing screwdriver 7 mm Fig 1 Exposed Conductor Length 12 mm G2RV SL700 G2RV SL...

Page 12: ...een dropped on the ground Dropping the product may adversely affect performance Confirm that the socket is securely attached to the mounting track before wiring If the socket is mounted insecurely it may fall and injure the operator Ensure that the socket is not charged during wiring and maintenance Not doing so may result in electric shock Do not pour water or cleansing agents on the product Doin...

Reviews: