TimeLine 71B008 Installation Manual Download Page 9

Micro Lynx ACG Option Card 

ECC NO. 1019 

Page 9

 

73630 REV. C 

PROCEDURE (continued): 

 

Figure 9.  Install the ACG Card 

12. If the M3 Card is fitted, insert the Option Card cable connector into J1 on the M3 

Card.  If the VITC Card is fitted, insert the Option Card cable connector into J1 on the 
VITC Card. 

13. Connect the other end of the cable into J3 on the Main Board.  The unused connectors 

will lie in the open area in the middle of the System Unit, unless you have option cards 
installed. 

14. Replace the top cover and the six phillips screws. 

15. Power up the System Unit.  The Micro Lynx will recognize the ACG Card on power 

up and the ACG LED on the System Unit OPTION Section will turn on.  Press 

SETUP

ACG

, to configure the card functions. 

 

Summary of Contents for 71B008

Page 1: ...TimeLine Part Number 71B009 ACG 2 Option Card PROCEDURE 1 Turn off the power and place the Micro Lynx System Unit on a static safe workstation Ground yourself and the workstation anti static mat 2 On...

Page 2: ...anel to the right of the SYSTEM TALLY connector The bracket is no longer needed keep the phillips screws Figure 1 Remove Support Bracket 6 Hold the Option Card bracket so that the large cutout is face...

Page 3: ...ay from the ACG Card as illustrated in Figure 3 Figure 3 Option Cable Installation 12 Position the ACG Card component side down with connector J1 toward the front of the System Unit Approximately 1 25...

Page 4: ...n Card cable connector into J1 on the VITC Card 18 Connect the other end of the cable into J3 on the Main Board The unused connectors will lie in the open area in the middle of the System Unit unless...

Page 5: ...acket 6 Remove the M3 Card if installed Remove the nut on the left threaded stud securing the front panel to the chassis 7 Hold the ACG Option Card bracket diagonally across the chassis with the cable...

Page 6: ...age 6 73630 REV C Install the ACG Option Card 9 Reinstall the M3 Card if it was removed The ACG Card is mounted on the left side of the System Unit above the M3 Card 10 Remove the mounting standoffs f...

Page 7: ...n the Option Card bracket Slide the ACG Card against the back panel so that the AES EBU connector and the O S OUT WORD OUT and CLOCK IN jacks are seated in the appropriate cutouts in the back panel In...

Page 8: ...the component side of the ACG Card The connector should be attached so that the cable falls away from the ACG Card as illustrated in Figure 3 8 Position the ACG Card component side down with connecto...

Page 9: ...tor into J1 on the VITC Card 13 Connect the other end of the cable into J3 on the Main Board The unused connectors will lie in the open area in the middle of the System Unit unless you have option car...

Reviews: