1. General Information

These instructions should be read carefully and retained for further reference  
and maintenance.

2. Safety

•  Before installation or maintenance, ensure the mains supply to the PIR  

light controller is switched off and the circuit supply fuses are removed  
or the circuit breaker turned off.

•  It is recommended that a qualified electrician is consulted or used for  

the installation of this PIR light controller and install in accordance  
with the current IEE wiring and Building Regulations.

•  Check that the total load on the circuit including when this PIR light controller 

is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.

Summary of Contents for SureTime STLB1000

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 180 PIR Light Controller Model STLB1000 Black Model STLW1000 White...

Page 2: ...d the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR light controller and insta...

Page 3: ...t 10 to 1000 Lux Day and night or night time only operation Pan Tilt Adjustment Pan left and right 45 Tilt down 35 Manual Override 6 hours max Warm up Time 60 seconds Operating Temperature 20 C to 40...

Page 4: ...TOWARDS See image B Therefore position the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extracto...

Page 5: ...tion 1 Mark the position of the mounting holes using the back plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden b...

Page 6: ...rect polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram Line the PIR light controller up with the back plate apply pressure to both sides of the unit until...

Page 7: ...V 50Hz mains supply and load cables into the terminal block as follows 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N Load Light Source Switch Live Brown or Red...

Page 8: ...ockwise Dusk Lux level setting fully clockwise Turn the power to the unit ON The lamp will immediately illuminate as the unit goes through its warm up period After approximately 1 minute the lamp will...

Page 9: ...s reached where the lamp illuminates 3 Leave the control knob set at this point At this position the unit should become operative at approximately the same level of darkness each evening Observe the o...

Page 10: ...witched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring connections Check the lamp if it s changeable If the lamp has failed replace Ensure the lamp is s...

Page 11: ...arantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 2 years of the date of purchase please return it to your supplier in the first year with p...

Page 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...